Request No. - CAR00383
Contractor Assessment Request Details
Assessment Type New
Vendor
Contractor Padmavati Electricals & Enterprises
Contractor Location Chh. Sambhajinagar
Contractor Email ID Padmavati Electricals & Enterprises
Plant Code 1101
 
Preliminary Details For Evaluation
Contractor Type Labour Contractor
Name of Company / Contractor PADMAVATI ELECTRICALS & ENTERPRISES
Contact Person Name AKSHAY SALUNKE
Contact Number 9595988883
Work Description LABOUR SUPPLIER & ELECTRICALS WORKS
Previous ETL Contracts ETL SANAND,ETL E-71
Existing Clientele ETL SANAND,ETL E-71, ETL B-2
Organizational Chart
Employees Head Count 45
Employees Deployed Count at ETL 45
Supervisors Count 3
Is Sub Contractor Nominated ? No
Sub Contractor
Contractors Financial Health & Capability (Turnover in INR) 5200000
C A Certificate 383_CACertificate_.jpeg
Does your last two years balance sheet shows profit? Yes
Balance Sheet 383_BalanceSheet_.jpeg
Do you have at least 3 years of experience for carrying out similar activity? No
Experience Certificate
 
Section 1 - Mandatory Requirement
Sr.No Requirement Text Options License / Registration No. / Policy No. Attachment Valid Till Score
1License under the Factory Act.1948 / Contract Labor Act / Shop ActComplied109016091903383_11__section1_.pdf31.12.20995
2Number of employees authorized to deploy as per licenseNot Applicable00383_12__section1_.pdf01.01.20255
3Is the organization registered for EPF?CompliedNGAUR2052250000383_13__section1_.pdf31.12.20995
4Is the organization registered for ESIC?Complied25000105130000699383_14__section1_.pdf31.12.20995
5Is the organization registered for GSTN?Complied27IYDPS4534Q1ZH383_15__section1_.pdf31.12.20995
6Workmen compensation Policy / Group InsuranceNot Applicable00383_16__section1_.pdf01.12.20255
7Are workers working hours complied with the current applicable law in the country?Complied00383_17__section1_.pdf01.12.20255
8Are wages paid on the basis of Minimum Wages Act?Complied00383_18__section1_.pdf01.12.20265
9Licensed Electrical Supervisor / Electrician If Applicable (For Electrical Work)Complied00088383_19__section1_.jpg31.12.20995
10Any complaint registered against the contractor in past under Labour lawsComplied00383_20__section1_.pdf01.12.20265
 
Total - 50
 
Section 2 - Safety Performance
Sr.No Requirement Text Answer Details Attachment Score
1No. of Accidents (Medical Treatment) in last 2 years0--383_21__section2_.pdf5
2No. of Fatalities (Verify from Govt. data / reference check)0--383_22__section2_.pdf5
3No. of Lost time injuries as per Factories Act 1948 (Injured person not able to work more than 48 hours from time of accident)0--383_23__section2_.pdf5
4No. of Fire Incident in last 2 years0--383_24__section2_.pdf5
5Has the organisation been prosecuted for an HSE breach or injury to an employee? Specify nos.0--383_25__section2_.pdf5
 
Total - 25
 
Section 3 - General EHS Systems
Sr.No Requirement Text Answer Details Attachment Score
1HSE Policy (Provide evidence by supplying copies of relevant documents)YesHSE POLICY383_26__section3_.jpeg5
2Induction and Training (provide relevant documents)YesSAFTY383_27__section3_.jpeg5
3PPE’s maintained in Good ConditionYesPPE,S383_28__section3_.jpeg5
4Health monitoring of Employees - Medical Check Up Done for employee’s as per Form 7 (date / Fitness Certificate from AFIH doctor)YesMEDICAL CERTIFICATE383_29__section3_.pdf5
5Does the organization regularly inspect and maintain hand tools, machinery (cranes, vehicles, hoists/lifting tools, etc.)No00
 
Total - 20
 
Section 4 - EHS Practices
Sr.No Requirement Text Answer Details Attachment Score
1Is the contract employee aware of Work Permit System / Work Permit Adherence?Yes383_31__section4_.pdf5
2Is the organization aware of Method Statement/ Method Statement Adherence?YesMethod Statement383_32__section4_.jpeg5
3Are the contract employees aware of Emergency Response Procedure?NoNO Emergency383_33__section4_.pdf0
4Has the organization conducted a HIRA study in past / or as a part of current practice?Not ApplicableNO5
5Does the organization have and follow safe work procedures, documents which define how risks relevant to the contracted activities are managed?Yes383_35__section4_.pdf5
 
Total - 20
 
Section 5 - Plant and Equipment
Sr.No Requirement Text Answer Details Attachment Score
1Are the tools and equipment used in good working condition?Yes383_36__section5_.pdf5
2Do the tools and equipment comply with standards such as ISI Mark / Energy Efficient 5 star rating guidelines?Yes383_37__section5_.pdf5
3Is the holding handle of equipment in good condition?Yes383_38__section5_.pdf5
4Are all plants and equipment compliant with the safety requirements? (including not damaged cables, no loose connections, equipped with 3 pin top)Yes383_39__section5_.pdf5
5Do contract employees have correct licenses / certificates to operate the plants and equipment?Yes383_40__section5_.jpg5
 
Total - 25
 
Total Score
Section Score
Section 1
Mandetory Requirement
50
Section 2
Safety Performance & System Awareness
25
Section 3
General EHS Systems
20
Section 4
EHS Practices
20
Section 5
Plant and Equipment
25
Total Score
140
 
The overall ranking of pre-qualification is 93 % (Professional)
 
 
Approval Process History
Role Employee Request Status Comments Updated On
Department Head400484 - Sopan KharcheApprovedDocuments are verified, Kindly crosscheckJan 16 2023 3:07PM
EHS856085 - Nilesh GujarResendIn declaration contractor mention mahalakshmi NameJan 18 2023 2:58PM
EHS856085 - Nilesh GujarApprovedOKJan 23 2023 3:31PM
HR401318 - Pramod SononeApprovedoKJan 27 2023 5:58PM
CorporateEHS400336 - Amarjeet KhatkarApprovedokJan 27 2023 6:04PM
HeadIR855987 - Kalyan PawarApprovedApprovedJan 28 2023 2:52PM