Request No. - CAR00386
Contractor Assessment Request Details
Assessment Type New
Vendor
Contractor OM SAI ENTERPRISES
Contractor Location MIDC WALUJ,BAJAJNAGAR
Contractor Email ID OM SAI ENTERPRISES
Plant Code 1159
 
Preliminary Details For Evaluation
Contractor Type Civil Fabrication
Name of Company / Contractor OM SAI ENTERPRISES
Contact Person Name PRADEEP HARI KAROLE
Contact Number 7796781516
Work Description FABRICATION AND PAINTING WORK
Previous ETL Contracts ETL-K-226/2,K-120,E-71,L-6
Existing Clientele FORBES AND WOKHAD
Organizational Chart 386_OrganizationalChart_.pdf
Employees Head Count 5
Employees Deployed Count at ETL 4
Supervisors Count 1
Is Sub Contractor Nominated ? No
Sub Contractor
Contractors Financial Health & Capability (Turnover in INR) 722122
C A Certificate 386_CACertificate_.pdf
Does your last two years balance sheet shows profit? Yes
Balance Sheet 386_BalanceSheet_.pdf
Do you have at least 3 years of experience for carrying out similar activity? Yes
Experience Certificate 386_ExperienceCertificate_.pdf
 
Section 1 - Mandatory Requirement
Sr.No Requirement Text Options License / Registration No. / Policy No. Attachment Valid Till Score
1License under the Factory Act.1948 / Contract Labor Act / Shop ActComplied282207678313386_11__section1_.pdf15.12.20245
2Number of employees authorized to deploy as per licenseComplied282207678313386_12__section1_.pdf30.12.20245
3Is the organization registered for EPF?Complied10001151225AUR386_13__section1_.pdf30.12.20245
4Is the organization registered for ESIC?Complied25000079000000699386_14__section1_.pdf15.12.20245
5Is the organization registered for GSTN?Complied27BXRPK1841G1Z9386_15__section1_.pdf15.12.20245
6Workmen compensation Policy / Group InsuranceComplied45240636220100000022386_16__section1_.pdf15.12.20245
7Are workers working hours complied with the current applicable law in the country?CompliedDeclaration386_17__section1_.pdf15.12.20245
8Are wages paid on the basis of Minimum Wages Act?CompliedDeclaration386_18__section1_.pdf15.12.20245
9Licensed Electrical Supervisor / Electrician If Applicable (For Electrical Work)Not Applicable5
10Any complaint registered against the contractor in past under Labour lawsCompliedDeclaration386_20__section1_.pdf15.12.20245
 
Total - 50
 
Section 2 - Safety Performance
Sr.No Requirement Text Answer Details Attachment Score
1No. of Accidents (Medical Treatment) in last 2 years0Declaration386_21__section2_.pdf5
2No. of Fatalities (Verify from Govt. data / reference check)0Declaration386_22__section2_.pdf5
3No. of Lost time injuries as per Factories Act 1948 (Injured person not able to work more than 48 hours from time of accident)0Declaration386_23__section2_.pdf5
4No. of Fire Incident in last 2 years0Declaration386_24__section2_.pdf5
5Has the organisation been prosecuted for an HSE breach or injury to an employee? Specify nos.0Declaration386_25__section2_.pdf5
 
Total - 25
 
Section 3 - General EHS Systems
Sr.No Requirement Text Answer Details Attachment Score
1HSE Policy (Provide evidence by supplying copies of relevant documents)YesDeclaration386_26__section3_.pdf5
2Induction and Training (provide relevant documents)YesDeclaration386_27__section3_.pdf5
3PPE’s maintained in Good ConditionYesDeclaration386_28__section3_.pdf5
4Health monitoring of Employees - Medical Check Up Done for employee’s as per Form 7 (date / Fitness Certificate from AFIH doctor)YesDeclaration386_29__section3_.pdf5
5Does the organization regularly inspect and maintain hand tools, machinery (cranes, vehicles, hoists/lifting tools, etc.)YesDeclaration386_30__section3_.pdf5
 
Total - 25
 
Section 4 - EHS Practices
Sr.No Requirement Text Answer Details Attachment Score
1Is the contract employee aware of Work Permit System / Work Permit Adherence?YesDeclaration386_31__section4_.pdf5
2Is the organization aware of Method Statement/ Method Statement Adherence?YesDeclaration386_32__section4_.pdf5
3Are the contract employees aware of Emergency Response Procedure?YesDeclaration386_33__section4_.pdf5
4Has the organization conducted a HIRA study in past / or as a part of current practice?YesDeclaration386_34__section4_.pdf5
5Does the organization have and follow safe work procedures, documents which define how risks relevant to the contracted activities are managed?YesDeclaration386_35__section4_.pdf5
 
Total - 25
 
Section 5 - Plant and Equipment
Sr.No Requirement Text Answer Details Attachment Score
1Are the tools and equipment used in good working condition?YesDeclaration386_36__section5_.pdf5
2Is the holding handle of equipment in good condition?YesDeclaration386_38__section5_.pdf5
3Are all plants and equipment compliant with the safety requirements? (including not damaged cables, no loose connections, equipped with 3 pin top)YesDeclaration386_39__section5_.pdf5
4Do contract employees have correct licenses / certificates to operate the plants and equipment?YesDeclaration386_40__section5_.pdf5
5Do the tools and equipment comply with standards such as ISI Mark / Energy Efficient 5 star rating guidelines?YesDeclaration386_37__section5_.pdf5
 
Total - 25
 
Total Score
Section Score
Section 1
Mandetory Requirement
50
Section 2
Safety Performance & System Awareness
25
Section 3
General EHS Systems
25
Section 4
EHS Practices
25
Section 5
Plant and Equipment
25
Total Score
150
 
The overall ranking of pre-qualification is 100 % (Professional)
 
 
Approval Process History
Role Employee Request Status Comments Updated On
Department Head851632 - Shashi Bhushan KumarApprovedPlease Check & Process for next .Jan 11 2023 3:43PM
EHS400358 - Piyush JaiswalResendA) Kindly provide Section no. 1 Question 2 attachment. As per license, 9 workers can be deployed so, same attachment can be uploaded. B) Kindly provide attachment of HSE Policy in Section no. 3 C) Section no. 4- Make a method statement which covers all details of activity with hazard associated with it and what controls you are going to implement to eliminate/reduce risk related to hazard. D) User department need to ensure HIRA of all activity and make contractor aware of ETL HIRA Format. E)Jan 11 2023 3:50PM
EHS400358 - Piyush JaiswalApprovedIt is okay. HR Team- Please ensure EPF applicability and deployment of only 9 contractors workers as per license.Jan 23 2023 6:20PM
HR400905 - Sandeep PathakResendDear Sir, Please complete the statutory documents requirements it is mandatory .Feb 3 2023 9:12AM
HR400905 - Sandeep PathakResendDear sir , Please complete the statutory requirement .Feb 3 2023 12:30PM
HR400905 - Sandeep PathakApprovedStatutory Documents VerifiedFeb 3 2023 4:41PM
CorporateEHS400336 - Amarjeet KhatkarApproved0kFeb 3 2023 4:54PM
HeadIR855987 - Kalyan PawarApprovedApprovedFeb 7 2023 11:04AM