Request No. - CAR02359
Contractor Assessment Request Details
Assessment Type New
Vendor
Contractor Shree Sai krupa
Contractor Location Chakan
Contractor Email ID Shree Sai krupa
Plant Code 1115
 
Preliminary Details For Evaluation
Contractor Type Labour Contractor
Name of Company / Contractor Shree Sai Krupa
Contact Person Name Vinod Gajanan Lahane
Contact Number 8369087165
Work Description Manpower Supply
Previous ETL Contracts 0
Existing Clientele Endurance Technologiers Limited
Organizational Chart
Employees Head Count 50
Employees Deployed Count at ETL 18
Supervisors Count 1
Is Sub Contractor Nominated ? No
Sub Contractor
Contractors Financial Health & Capability (Turnover in INR) 500000
C A Certificate 2359_CACertificate_.pdf
Does your last two years balance sheet shows profit? No
Balance Sheet
Do you have at least 3 years of experience for carrying out similar activity? No
Experience Certificate
 
Section 1 - Mandatory Requirement
Sr.No Requirement Text Options License / Registration No. / Policy No. Attachment Valid Till Score
1License under the Factory Act.1948 / Contract Labor Act / Shop ActComplied24310003189683842359_11__section1_.pdf01.08.20915
2Number of employees authorized to deploy as per licenseComplied24310003189683842359_12__section1_.pdf01.12.20365
3Is the organization registered for EPF?CompliedPUPUN33276210002359_13__section1_.pdf01.03.20365
4Is the organization registered for ESIC?Complied330013899200010152359_14__section1_.pdf01.03.20365
5Is the organization registered for GSTN?Complied27AFIFS6734G1ZN2359_15__section1_.pdf29.02.20365
6Workmen compensation Policy / Group InsuranceComplied330013899200010152359_16__section1_.pdf01.12.20365
7Are workers working hours complied with the current applicable law in the country?Complied24310003189683842359_17__section1_.pdf01.12.20365
8Are wages paid on the basis of Minimum Wages Act?Complied24310003189683842359_18__section1_.pdf01.12.20365
9Licensed Electrical Supervisor / Electrician If Applicable (For Electrical Work)Not Applicable5
10Any complaint registered against the contractor in past under Labour lawsNot Applicable5
 
Total - 50
 
Section 2 - Safety Performance
Sr.No Requirement Text Answer Details Attachment Score
1No. of Accidents (Medical Treatment) in last 2 years0No Accident5
2No. of Fatalities (Verify from Govt. data / reference check)0No Fatal5
3No. of Lost time injuries as per Factories Act 1948 (Injured person not able to work more than 48 hours from time of accident)0No Lost Injury5
4No. of Fire Incident in last 2 years0No Fire Incident5
5Has the organisation been prosecuted for an HSE breach or injury to an employee? Specify nos.0No5
 
Total - 25
 
Section 3 - General EHS Systems
Sr.No Requirement Text Answer Details Attachment Score
1HSE Policy (Provide evidence by supplying copies of relevant documents)YesHSC Policy2359_26__section3_.pdf5
2Induction and Training (provide relevant documents)YesInduction Given by EHS officer2359_27__section3_.pdf5
3PPE’s maintained in Good ConditionYes5
4Health monitoring of Employees - Medical Check Up Done for employee’s as per Form 7 (date / Fitness Certificate from AFIH doctor)YesMedical examination done2359_29__section3_.jpg5
5Does the organization regularly inspect and maintain hand tools, machinery (cranes, vehicles, hoists/lifting tools, etc.)YesNo Applicable for me5
 
Total - 25
 
Section 4 - EHS Practices
Sr.No Requirement Text Answer Details Attachment Score
1Is the contract employee aware of Work Permit System / Work Permit Adherence?YesNot Applicable5
2Is the organization aware of Method Statement/ Method Statement Adherence?Yes5
3Are the contract employees aware of Emergency Response Procedure?Yes5
4Has the organization conducted a HIRA study in past / or as a part of current practice?Yes5
5Does the organization have and follow safe work procedures, documents which define how risks relevant to the contracted activities are managed?Yes5
 
Total - 25
 
Section 5 - Plant and Equipment
Sr.No Requirement Text Answer Details Attachment Score
1Are the tools and equipment used in good working condition?Not Applicable5
2Do the tools and equipment comply with standards such as ISI Mark / Energy Efficient 5 star rating guidelines?Not Applicable5
3Is the holding handle of equipment in good condition?Not Applicable5
4Are all plants and equipment compliant with the safety requirements? (including not damaged cables, no loose connections, equipped with 3 pin top)Not Applicable5
5Do contract employees have correct licenses / certificates to operate the plants and equipment?Not Applicable5
 
Total - 25
 
Total Score
Section Score
Section 1
Mandetory Requirement
50
Section 2
Safety Performance & System Awareness
25
Section 3
General EHS Systems
25
Section 4
EHS Practices
25
Section 5
Plant and Equipment
25
Total Score
150
 
The overall ranking of pre-qualification is 100 % (Professional)
 
 
Approval Process History
Role Employee Request Status Comments Updated On
Department Head851773 - Gorakhnath GoniApprovedokAug 31 2024 1:03PM
HR401510 - Amit PawarResendPolicy not attachedAug 31 2024 1:08PM
HR401510 - Amit PawarApprovedoKAug 31 2024 4:21PM
EHS401422 - Atul KhandveApprovedOkAug 31 2024 4:32PM
EHS401422 - Atul KhandveApprovedOkAug 31 2024 4:32PM
CorporateEHS400326 - Sunil SonarApprovedOK APPROVEDSep 3 2024 11:42AM
HeadIR855987 - Kalyan PawarApprovedApprovedSep 9 2024 11:23AM