QFR No - 7000844025
Defect Details
NC No. 7000844025
NC Date 22/06/2022
NC Submission Date
Part No. 520JF00123
Part Name PISTON GROOVED
Supplier Name & Code 100176-GKN SINTER METALS PRIVATE LIMI
ETL Plant 1126-ETL Pantnagar
Defect Details RUSTY-Rusty
 
1. Problem Description
Defect Description Quality issues of Rust, heavy dents on face due to loose packing (Without separator).
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 9716
Is Defect Repeatative? Yes
Defect Sketch / Photo yjs2ms4h4ye1mpfi2hldotw3.png
Supplier Communication Details
Quality Head Email ID Manojkumar.Mali@gknpm.com
Plant Head/CEO Email ID Manojkumar.Mali@gknpm.com
MD Email ID Rajesh.Mirani@gknpm.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
46000
35000
0
25000
120000
226000
Check Qty
46000
35000
0
25000
120000
226000
NG Qty
9716
4612
0
2611
120000
136939
 
Scrap 9716
Rework 0
Under Deviation 0
Containment Action
All stock lying at ETL is under segregation. Quality Alert raised at Inhouse & Tier 2 Location .,Warehouse & Inhouse stock is under segregation
 
3. Process Flow
Process Flow Description
Forming - Sintering - Sizing -Machining - Oil dipping -Packing - PDI Inspection
 
4. Process Details
Process / Operation Machining
Outsource Yes
Machine / Cell Oil dipping
Machine / Cell No. NA
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodParts exposed to the coolant mixed dewatering oilParts are found in contact with coolent mixed dewatering oil.X
MaterialParts Metallurgy NGParts are OK to the metallurgical check and found okO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100
7. Root Cause Analysis (Occurance)
Why 1 Parts exposed to the coolant mixed dewatering oil
Why 2 Parts are in contact with coolant mixed dewatering oil
Why 3 Parts carrying tray is resting at bottom side of the tank
Why 4 Tray resting pads are at the bottom of the oil tank.
Why 5 Tray resting pads are at the bottom of the oil tank.
Root Cause (Occurance) Parts are in contact with coolant mixed dewatering oil
 
Root Cause Analysis (Outflow)
Why 1 Skipped in IN process and Final inspection
Why 2 Parts was found ok during inspection
Why 3 Parts was rust free after final inspection
Why 4 After final inspection , parts was ok at GKN pdi
Why 5 Parts gets rusty after clearing the material from PDI
Root Cause (Outflow) Parts gets rusty afeter clearing the material from PDI
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowRefreshment training is provided to all operators and inspectors thru One Point lesson and quality alert.Yogesh Wase10/06/202224/06/2022Completed
Occurance1. Dewatering tank design will be modified as stopper (Resting pads) for tray resting will placed upward to avoid the contact with coolant mixed oil.Yogesh Wase24/06/202210/06/2022Completed
OutflowSupervisor will re verify lots before dispatch after packingYogesh Wase10/06/202210/06/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details NA
Inspection Method Other
Other Inspection Method NA
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100
10. Evidance of Countermeasure
Occurance (Before) Dewatering Tray Rest at the Bottom of the Oil Tank Coolant mix oil found at same area Draining frequency is Once/Day Parts get affected due to coolant mix oil
182_Occurance_Before.xlsx
Occurance (After) Design of Dewatering Tank Is Changed Tray Resting Area Fixed near to mid of tank,Frequency of coolant drain is changed by Once /Hr.Parts not affected due to coolant mix oil
182_Occurance_After.xlsx
Outflow (Before) NA
182_Outflow_Before.xlsx
Outflow (After) Supervisor will re verify lots before despatch after packing.
182_Outflow_After.xlsx
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant NA
 
12. Document Review
Documents ControlPlan, PFMEA
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 1
Reason for submission Found OK