Defect Details DEPTH O/SIZE.-Depth over size
 
1. Problem Description
Defect Description Depth found Over size Observed 7.20,7.34 against 7±0.10 mm
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 114
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID quality@apw3.co.in
Plant Head/CEO Email ID kurund.ma@sharp-engineers.com
MD Email ID urkhandelwal@sharp-engineers.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
29000
0
0
5000
0
34000
Check Qty
29000
0
0
5000
0
34000
NG Qty
114
0
0
5
0
119
 
Scrap 0
Rework 119
Under Deviation 0
Containment Action
Segregation done for all the pipeline material & Dial type gauge made available in place of PPG on all the stages & Stage wise skill matrix defined for operator. Q gate license implemented for inspectors. OPL displayed on machine as well as inspection stages.
 
3. Process Flow
Process Flow Description
10) Parting ,Drilling & angle 2.7° 20) Ø8.50 chamfering 30) Grinding Operation 40) Plating, 50) Final Inspection, 60) Pre-dispatch inspection, 70) Packing & Dispatch
 
4. Process Details
Process / Operation 10) Parting ,Drilling & angle 2.7°
Outsource No
Machine / Cell TRAUB MACHINE SHOP
Machine / Cell No. SE/ALM/03
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ManSemi-skilled manpower, inadequate knowledge of process/operationsSemi-skilled operator was working on machine for parting & drilling operation.O
Toolworn outTool life monitoring existO
MaterialBend bar in the raw materialbar observed bend at machining stage.X
Method100%Checking by relation type gauge, Dial type gauge required for sampling inspection.Dial type gauge not evident for sampling basis inspection.X
Machineinaccurate machine/variations in machineAll the machine are ok and preventive maintenance being done as per defined frequency.O
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Dial type gauge .
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 1:1
7. Root Cause Analysis (Occurance)
Why 1 DIM 7.0+/-0.1 under size
Why 2 Bar bend (Raw material Ø18.05) & uneven movement while machining.
Why 3 Excess bar length 5-6 meter
Why 4 Length requirement not given to RM supplier
Why 5
Root Cause (Occurance) Excess length of bar Ø18.05mm (5-6 meter)
 
Root Cause Analysis (Outflow)
Why 1 DIM 7.0+/-0.1 under size
Why 2 Inspection by Spl. concentricity checking gauge
Why 3 Attribute type gauge
Why 4 Dial type gauge not available.
Why 5
Root Cause (Outflow) Dial type gauge not in used while checking DIM 7.0+/-0.1mm.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowDial type gauge and comparator stand provided for sampling basis inspection as per SSPN IS:2500Mr. Shaikh L..N11/07/202208/07/2022Completed
OccuranceRaw material ena1a Ø18.05mm total length reduced from 5/6 meter to 3/4 meter.Mr. Datta Pandher11/07/202208/07/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Dial type gauge and comparator stand provided for sampling basis inspection as per SSPN IS:2500 and 100% inspection by Spl. concentricity checking gauge.
Inspection Method Other
Other Inspection Method Dial type gauge.
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 32:1200
10. Evidance of Countermeasure
Occurance (Before) Excess length of bar Ø18.05mm (5-6 meter).
192_Occurance_Before.jpg
Occurance (After) Bar length of raw material Ø18.05mm reduced from 5/6 meter to 3/4 meter.
192_Occurance_After.jpg
Outflow (Before) Inspection by Spl. concentricity checking gauge, Dial type gauge not in used while checking DIM 7.0+/-0.1mm.
192_Outflow_Before.pptx
Outflow (After) Dial type gauge and comparator stand provided for sampling basis inspection as per SSPN IS:2500
192_Outflow_After.pptx
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant CAP OIL LOCK LML/ DF
 
12. Document Review
Documents ControlPlan, PFMEA, WISOP
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 1
Reason for submission OK