QFR No - 7000890664
Defect Details
NC No. 7000890664
NC Date 16/01/2023
NC Submission Date
Part No. S2BG02502B
Part Name BRACKET UN P/C KTEP
Supplier Name & Code 100973-TESMO MOTORCAST PRIVATE LIMITE
ETL Plant 1116-ETL K-120 Suspension
Defect Details THREADING NOT OK-Threading and Casting Defect
 
1. Problem Description
Defect Description Major & fitment related defects like threading NG, Blow holes, cracks etc. repetitively observed.
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 1100
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID rkhare@tesmomotorcast.com
Plant Head/CEO Email ID harish.bala@tesmomotorcast.com
MD Email ID svkallani@tesmomotorcast.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1100
0
0
6000
13000
20100
Check Qty
1100
0
0
6000
13000
20100
NG Qty
1100
0
0
20
0
1120
 
Scrap 20
Rework 0
Under Deviation 0
Containment Action
Perpendicularity checking gauge made and start hourly checking
 
3. Process Flow
Process Flow Description
PDC - Deburring - Remer - surface treatment - Camper - tapping - Air Cleaning - Packing
 
4. Process Details
Process / Operation PDC
Outsource No
Machine / Cell 250-2
Machine / Cell No. 2
5. Problem Analysis
Type Possible Cause Fact Verification Jud
Materialcore pin hardness not okhardness testing report checkO
Toolside core not proper opengaugeO
ToolDie Core Side Pin BendPerpendicularity gaugeO
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size Every Hr
7. Root Cause Analysis (Occurance)
Why 1 Tap not gone up to required depth
Why 2 Tap jam while completing its cycle
Why 3 Hole pin perpendicularity not ok
Why 4 Die core pin bend
Why 5 Pin hardness not as per requirement
Root Cause (Occurance) Core pin hardness not freeze.
 
Root Cause Analysis (Outflow)
Why 1 Tap not gone up to required depth
Why 2 Tap jam while completing its cycle
Why 3 Hole pin perpendicularity not ok
Why 4 Die core pin perpendicularity not ok
Why 5 Perpendicularity not check
Root Cause (Outflow) Core pin Perpendicularity checking frequency not defined.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowHourly pin hole Perpendicularity checkingRahul27/06/2023Pending
OccurancePin hardness freezeSachin27/06/2023Pending
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Perpendicularity checking started on hourly check on PDC
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 500
10. Evidance of Countermeasure
Occurance (Before) Threading not OK
331_Occurance_Before.jpeg
Occurance (After) Threading ok
331_Occurance_After.jpeg
Outflow (Before) THREADING NOTOK
331_Outflow_Before.jpeg
Outflow (After) THREADING OK
331_Outflow_After.jpeg
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant kwpk
 
12. Document Review
Documents InspCheckSheet
Specify Other Document GAUGE CHEKING
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission