QFR No - 7000951520
Defect Details
NC No. | 7000951520 |
NC Date | 10/10/2023 |
NC Submission Date | |
Part No. | F1LG00902B |
Part Name | SEAT PIPE -K86A |
Supplier Name & Code | 101263-SINGLA PRECISION SCREWS |
ETL Plant | 1136-ETL Suspension Sanand |
Defect Details | LENGTH UNDERSIZE-Total length undersize |
1. Problem Description
Defect Description | Seat pipe K86 total length found undersize 146.47 mm against specification 152 -0.2 mm |
Detection Stage | Inprocess |
Problem Severity | Fitment |
NG Quantity | 72 |
Is Defect Repeatative? | No |
Defect Sketch / Photo |
Supplier Communication Details
Quality Head Email ID | quality@singlaprecision.com |
Plant Head/CEO Email ID | quality@singlaprecision.com |
MD Email ID | aditya@singlaprecision.com |
2. Stock Details & action taken for NG parts
Location | ETL End | Warehouse | Transit | Supplier FG | Supplier WIP | Total |
---|---|---|---|---|---|---|
Total Qty |
8000
|
0
|
0
|
0
|
0
|
8000
|
Check Qty |
8000
|
0
|
0
|
0
|
0
|
8000
|
NG Qty |
72
|
0
|
0
|
0
|
0
|
72
|
Scrap | 72 |
Rework | 0 |
Under Deviation | 0 |
Containment Action |
---|
Stock check 100% at our end. |
3. Process Flow
Process Flow Description |
---|
Forging-Drilling& Flash Turning-Rough Grinding-CNC-1st-CNC-2nd-Punching-Filling-Reaming-Tapping-Final Grinding-Final Inspection-Packing |
4. Process Details
Process / Operation | Packing |
Outsource | No |
Machine / Cell | 01 |
Machine / Cell No. | 02 |
5. Problem Analysis
Type | Possible Cause | Fact Verification | Jud |
---|---|---|---|
Method | Two types pf samples packed at same time & same place. | Yes | O |
6. Inspection Method Analysis (Current)
Inspection Method | Other |
Other Inspection Method | Sampling |
Check Point at Final Inspection | Yes |
Checking Freq. | Sampling |
Sampling | No |
Sample Size | 80 |
7. Root Cause Analysis (Occurance)
Why 1 | Total length short pcs. reached at customer end |
Why 2 | The problem occurred at packing stage |
Why 3 | Two types of samples packed at same time same place |
Why 4 | Operator was unaware and some mix material packed in boxes |
Why 5 | So mixed material reached at customer end |
Root Cause (Occurance) | Two types of samples packed at same time & same place. |
Root Cause Analysis (Outflow)
Why 1 | Total length short pcs. reached at customer end |
Why 2 | 100% inspection is not done at packing stage |
Why 3 | Inspection is also as per sampling plan |
Why 4 | So final inspection person not caught this defect |
Why 5 | So NG parts dispatched to customer end |
Root Cause (Outflow) | Two types of samples packed at same time & same place. |
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type | Countermeasure Details | Responsibility | Target Date | Actual Date | Status |
---|---|---|---|---|---|
Outflow | Single sample packed at a time | Quality Head | 16/10/2023 | 16/10/2023 | Completed |
9. Inspection Method After Customer Complaint
Change In Inspection System | No |
Change Details | No |
Inspection Method | Instrument |
Other Inspection Method | |
Check Point at Final Inspection | Yes |
Checking Freq. | Sampling |
Sampling | No |
Sample Size | as per pla |
10. Evidance of Countermeasure
Occurance (Before) |
Two types of samples packed at a time on same place 572_Occurance_Before.jpeg |
Occurance (After) |
some type material use deference bin 572_Occurance_After.jpeg |
Outflow (Before) |
Two types of samples packed at a time on same place not use different bin some types bin use 572_Outflow_Before.jpeg |
Outflow (After) |
Single sample packed at a time and deferent bin use 572_Outflow_After.jpeg |
11. Horizontal Deployment
Horizontal Deployment Required | Yes |
Applicable Machine / Model / Plant | Packing |
12. Document Review
Documents | WISOP |
Specify Other Document | OPL |
13. Effectiveness Of Action
Reviewed Quantity | 5 |
Reason for submission | Seat pipe K86 total length found undersize 146.47 mm against specification 152 -0.2 mm |