QFR No - 7000966074
Defect Details
NC No. 7000966074
NC Date 08/12/2023
NC Submission Date
Part No. 520FW04702
Part Name CLUTCH HOUSING FULL FINISHED-K70
Supplier Name & Code 100656-MADHURA DIE CAST PVT.LTD
ETL Plant 1132-ETL K-226/1 TRANSMISSION
Defect Details OXDISED-Oxidised issue
 
1. Problem Description
Defect Description Heavy Oxidation Issue
Detection Stage Inprocess
Problem Severity Aesthetic
NG Quantity 504
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID madhuradiecast@gmail.com
Plant Head/CEO Email ID madhuradiecast@gmail.com
MD Email ID madhuradiecast@gaikegroup.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1000
1000
0
500
300
2800
Check Qty
1000
1000
0
500
300
2800
NG Qty
12
0
0
0
0
12
 
Scrap 12
Rework 0
Under Deviation 0
Containment Action
.100% Stock segregate at customer end and Supplier end stock.
 
3. Process Flow
Process Flow Description
1.Casting 2. fetling 3. CNC 1st Set-up 4.CNC 2nd Set-up 5.Final Inspection
 
4. Process Details
Process / Operation Casting
Outsource No
Machine / Cell HPDC
Machine / Cell No. 01
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ManUnskill Operator On machine.Skill Matrix Varified & Found OK.O
Machinewater was leakage in dieChecking water leakage & Found okO
Toolair spray gun is not in working conditionchecking air spray gun found in working conditionO
MethodMIDC regular water supply was not availableMIDC regular water supply was not availableX
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual Inspection
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 1:1
7. Root Cause Analysis (Occurance)
Why 1 Oxidised Issue
Why 2 Because water PH value is high.
Why 3 We used Tanker water
Why 4 Because MIDC regular water supply was not available .
Why 5
Root Cause (Occurance) Because MIDC regular water supply was not available .
 
Root Cause Analysis (Outflow)
Why 1 Oxidised Issue
Why 2 100% inspection not done
Why 3
Why 4
Why 5
Root Cause (Outflow) checking was sampling basis
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Occurance1.Regular MIDC water supply is started. 2. If MIDC Water is not available we will discuss with Management.PRODUCTION SUPERVISOR21/12/202320/12/2023Completed
Outflow1. 100% die coated part separated & its inspection started. 2.Visual checking Eye Sequence Chart Displayed on Board.QUALITY SUPERVISOR21/12/202320/12/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 1. 100% die coated part separated & its inspection started. 2.Visual checking Eye Sequence Chart Displayed on Board.
Inspection Method Other
Other Inspection Method Visual checking
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 1:1
10. Evidance of Countermeasure
Occurance (Before) 1.MIDC regular water supply was not available .
610_Occurance_Before.jpg
Occurance (After) 1.Regular MIDC water supply is started. 2. If MIDC Water is not available we will discuss with Management.
610_Occurance_After.jpg
Outflow (Before) 100% inspection not done
610_Outflow_Before.jpg
Outflow (After) 1. 100% die coated part separated & its inspection started. 2.Visual checking Eye Sequence Chart Displayed on Board.
610_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant NA
 
12. Document Review
Documents ControlPlan, PFMEA, WISOP, InspCheckSheet
Specify Other Document EYE SEQUENCE CHART
 
13. Effectiveness Of Action
Reviewed Quantity 1000
Reason for submission Alternative of MIDC Water not available -Again possibility of defect generation if MIDC water not available