QFR No - 7001052680
Defect Details
NC No. 7001052680
NC Date 11/09/2024
NC Submission Date
Part No. S1AB00612B
Part Name ADJUSTER PLATED
Supplier Name & Code 100782-NICE STEEL INDUSTRIES
ETL Plant 1136-ETL Suspension Sanand
Defect Details DIAMETER OVER SIZE-ID Oversize
 
1. Problem Description
Defect Description ID oversize observed 31.70 mm against specification 30.50~30.70 mm
Detection Stage Receipt
Problem Severity Safety
NG Quantity 8000
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID ppc.nice@batragroup.biz
Plant Head/CEO Email ID ho.nice@batragroup.biz
MD Email ID hitesh@batragroup.biz
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
8000
2000
0
2000
2000
14000
Check Qty
8000
2000
0
2000
2000
14000
NG Qty
2034
122
0
96
98
2350
 
Scrap 0
Rework 2034
Under Deviation 0
Containment Action
1-Go and No Go gauge to be made 2- Part to be checked by DVC during setup and in-process for the ID
 
3. Process Flow
Process Flow Description
10 RECEIVING INSPECTION 20 STORAGE 30 BLANKING 40 1st BENDING ( `U` BENDING) 50 FINAL BENDING ( ROUNDING ) 60 MIG WELDING 70 FLAIRING 1st 80 FLAIRING 2nd 90 ID SIZING 100 SIDE GRINDING & BUFFING 110 REROUNDING 120 BROACHING 130 HEAD GRINDING 140 OUTSIDE MOVEMENT FOR PLATING 150 STORAGE & RQC INSP. OF PLATED MATERIAL 160 FINAL INSPECTION 170 PACKING & DISPATCH
 
4. Process Details
Process / Operation Re-rounding
Outsource No
Machine / Cell PP
Machine / Cell No. 10 to 30 Ton
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ManUntrained operatorOperator is skilled but not regular on this partO
ManUnskilled operatorSkill matrix availableX
MachineMachine capacity was lower side usedMachine checked and found okX
MethodPart was not properly rest in mandrelmandrel length was same as part lengthO
ToolMandrel sizeMandrel check and found length was same as part lengthO
Materialwrong material usedMaterial checked and found okX
MachineMachine capacity was higher side usedMachine checked and found okX
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size Visual
7. Root Cause Analysis (Occurance)
Why 1 Dia over size observed at customer end
Why 2 Id not maintained at leg area due to Part leg was not properly
Why 3 3 mm part leg area was in the air due to part not properly rest at re-round mandrel
Why 4 Mandrel length and part resting length was same
Why 5 Mandrel length was defined as per past experience according to other similar process/part
Root Cause (Occurance) 1- 3 mm part leg area was in the air due to part not properly rest at re-round mandrel 2-Madral length and part resting length was same
 
Root Cause Analysis (Outflow)
Why 1 Defective part not found ok PDI area
Why 2 Inspection was doing with plug gauge
Why 3 Plug gauge was defined for inspection
Why 4
Why 5
Root Cause (Outflow) Inspection was doing with plug gauge
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceMandrel length increased 33±3 mm from 24.0±2Nimit10/09/202410/09/2024Completed
OccuranceRe-rounding to be started at 2 location on part by 2 strokeNimit15/09/202412/09/2024Completed
OutflowOPL displayedPrahlad10/09/202409/09/2024Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Part to be checked by DVC during setup and in-process for the ID
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size Revers
10. Evidance of Countermeasure
Occurance (Before) NA
1085_Occurance_Before.png
Occurance (After) SHEET ATATCHED
1085_Occurance_After.png
Outflow (Before) NA
1085_Outflow_Before.png
Outflow (After) SHEET ATTACHED
1085_Outflow_After.png
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant NA
 
12. Document Review
Documents ControlPlan, PFMEA, WISOP, InspCheckSheet
Specify Other Document NO
 
13. Effectiveness Of Action
Reviewed Quantity 5
Reason for submission ID oversize observed 31.70 mm against specification 30.50~30.70 mm