QFR No - 8000785385
Defect Details
NC No. 8000785385
NC Date 26/04/2022
NC Submission Date
Part No. 530CZ00102
Part Name DU BUSH
Supplier Name & Code 100037-BBL DAIDO PRIVATE LIMITED
ETL Plant 1136-ETL Suspension Sanand
Defect Details CHAMFER NOT DONE- WARRANTY ANALYSIS PART
 
1. Problem Description
Defect Description Uneven Chamfer and ID Coating Crumble observed in Warranty Return Parts, Also witnessed to supplier person.
Detection Stage Warranty
Problem Severity Function
NG Quantity 5
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID rajamani@bbldaido.com
Plant Head/CEO Email ID vinod@bbldaido.com
MD Email ID
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
5
0
0
0
0
5
Check Qty
5
0
0
0
0
5
NG Qty
5
0
0
0
0
5
 
Scrap 5
Rework 0
Under Deviation 0
Containment Action
Bush investigated and found ID chamfer found OK and Bush material PTFE composition found good , hence Oil leak is not related to DU Bush. Available Bush at BBLD found OK
 
3. Process Flow
Process Flow Description
RM Inspection - Slitting - Welding - Size rolling - Facing and chamfering -Pressing - Coining - Plating - Final Inspection - Despatch
 
4. Process Details
Process / Operation Facing and chamfering
Outsource No
Machine / Cell Bush Manufacturing line
Machine / Cell No. 5B-2
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodID Chamfer one side tool less depth of cutLess depth of cutX
 
6. Inspection Method Analysis (Current)
Inspection Method Instrument
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 20 nos per
7. Root Cause Analysis (Occurance)
Why 1 ID Chamfer one side tool less depth of cut
Why 2 Coil Feed to chamfering tool contact space less
Why 3 Chamfer coil movement waviness not consider to run the parts maximum side
Why 4 Control dimension not provided in the process drawing
Why 5
Root Cause (Occurance) Control dimension not provided in the process drawing
 
Root Cause Analysis (Outflow)
Why 1 Bush ID chamfer found NG
Why 2 Bush ID chamfer sampling ( 1 no per lot) inspection by contour
Why 3 Sampling not adequate to control the ID chamfer dimension
Why 4
Why 5
Root Cause (Outflow) Sampling not adequate to control the ID chamfer dimension
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Occurance1.Control dimension not provided in the process drawingT.Rajamani05/05/202205/09/2022Completed
OutflowVisual inspection limit sample provided to check the less chamferT.Rajamani05/05/202205/09/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details ID chamfer band modified as per customer required chamfer
Inspection Method Other
Other Inspection Method ID chamfer provided
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 20
10. Evidance of Countermeasure
Occurance (Before) Refer attached
77_Occurance_Before.pdf
Occurance (After) Refer attached
77_Occurance_After.pdf
Outflow (Before) Refer attached
77_Outflow_Before.pdf
Outflow (After) Refer attached
77_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant Not applicable
 
12. Document Review
Documents PFMEA, InspCheckSheet
Specify Other Document Process drawing
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission