QFR No - 8000788019
Defect Details
NC No. 8000788019
NC Date 19/05/2022
NC Submission Date
Part No. S1AB00612B
Part Name ADJUSTER PLATED
Supplier Name & Code 100782-NICE STEEL INDUSTRIES
ETL Plant 1136-ETL Suspension Sanand
Defect Details SHADE VARIATION-SHADE VARIATION
 
1. Problem Description
Defect Description Shade Variation i.e. Heavy Blueness observed
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 200
Is Defect Repeatative? No
Defect Sketch / Photo pebw2vym4iu2pqxmtsmh5bjd.png
Supplier Communication Details
Quality Head Email ID ppc.nice@batragroup.biz
Plant Head/CEO Email ID ho.nice@batragroup.biz
MD Email ID hitesh@batragroup.biz
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
0
500
1000
1000
1000
3500
Check Qty
0
500
1000
1000
1000
3500
NG Qty
0
0
0
500
0
500
 
Scrap 0
Rework 500
Under Deviation 0
Containment Action
RE-PLATING DONE IN ALL SUSPECTED MATERIAL
 
3. Process Flow
Process Flow Description
10- RECEIVING INSPECTION 20- STORAGE 30-BLANK 40- U-BENDING 50-ROUNDING 60-WELDING 70- FLARING 80- ID SIZING 90-SIDE GRINDING 100-BROACHING 110-HEAD GRINDING & BUFFING 120- OUT SIDE MOVEMENT FOR PLATING 130-STORAGE & RQC OF PLATED MATERIAL 140-FINAL INSPECTION 150-PACKING & DISPATCH
 
4. Process Details
Process / Operation PLATING
Outsource Yes
Machine / Cell PASSIVATION TANK
Machine / Cell No. PASSIVATION TANK
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MaterialWRONG MATERIAL USEDMATERIAL OK AS PER DRAWINGO
ToolTOOL WEAR OUTTOOL FOUND OKO
MethodPASSIVATION TIME WAS LESSPROCESS CHECKSHEETX
ManUNTRAINED OPERATORSKILL MATRIX AVAILABLEO
MachineMACHINE CAPACITY NOT OKCAPACITY OK AS PER DEFINEDO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method CHEMICAL ANALYSIS
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size AS PER
7. Root Cause Analysis (Occurance)
Why 1 PASSIVATION COLOUR CHANGED
Why 2 PASSIVATION NOT DONE AS PER REQUIERMENT
Why 3 PASSIVATION TIME WAS LESS
Why 4 LOT REMOVED FROM TANK BEFORE REQUIERD TIME
Why 5 MANUAL CONTROL
Root Cause (Occurance) PASSIVATION TIME WAS LESS
 
Root Cause Analysis (Outflow)
Why 1 WRONG PASSIVATION PARTS DISPATCHED
Why 2 BOTH PASSIVATION PARTS PASSED BY FINALMINSPECTOR
Why 3 LIMIT SAMPLES WAS NOT DEFINED
Why 4
Why 5
Root Cause (Outflow) MASTER SAMPLE WAS NOT AVAILABLE
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccurancePLC LINE IMPLEMENTED FOR ALL PARAMETER CONTROLLING LIKE TIME , TEMP ETCNICE24/05/202215/05/2022Completed
OutflowSAMPLE PROVIDED TO FINAL INSPECTION TEAM FOR COLOUR VARATIONNICE22/05/202215/05/2022Completed
OccurancePASSIVATION TIME FROZENNICE STEEL IND01/11/202215/05/2022Inprocess
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 100% VIUSAL INSPECTION STARTED
Inspection Method Other
Other Inspection Method VISUAL WITH SAMPLE
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size OPL
10. Evidance of Countermeasure
Occurance (Before) BEFORE - PROCESS/LINE PICTURE ATTACHED
140_Occurance_Before.jpg
Occurance (After) AFTER-PROCESS/LINE PICTURE ATTACHED
140_Occurance_After.jpg
Outflow (Before) BEFORE - CP FILE ATTACHED
140_Outflow_Before.pdf
Outflow (After) AFTER-CP FILE ATTACHED
140_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant NO APPLICABLE
 
12. Document Review
Documents ControlPlan
Specify Other Document NOT REQUIRED
 
13. Effectiveness Of Action
Reviewed Quantity 0
Reason for submission Problem Analysis Fact Verification observation to be written in details. Also Occurence side why why analysis side caus and action are not adequate. Flow side Countermeasuers are not taken and Documents reviewed and updated are not adequate.