QFR No - 8000789394
Defect Details
NC No. 8000789394
NC Date 30/05/2022
NC Submission Date
Part No. S2BY03451B
Part Name CANISTER SQR GROOVE LEAK TESTED
Supplier Name & Code 100465-PN DIE CASTINGS PVT LTD
ETL Plant 1126-ETL Pantnagar
Defect Details DIMN.O/SIZE.-GR0OVE WIDTH OVERSIZE
 
1. Problem Description
Defect Description Groove Dim. 4.10+0.10 observed upto 4.32,4.40,4.45 and the Step height 2±0.10 just below the Groove observed as 1.64,1.53,1.62. and Dim. 1.50+0.10 observed as 1.24,1.36,1.31
Detection Stage Inprocess
Problem Severity Fitment
NG Quantity 1335
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID qualityqh@bansaldiecastings.com
Plant Head/CEO Email ID gm@bansaldiecastings.com
MD Email ID piyush@bansaldiecastings.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1500
0
0
3000
100
4600
Check Qty
1500
0
0
3000
100
4600
NG Qty
1500
0
0
3000
100
4600
 
Scrap 4600
Rework 0
Under Deviation 0
Containment Action
1.Segrigated all store ,wip & Assly area at customer end(1500 qty) by the leak testing machine and found All part not ok- Akshay 2.Segrigated all store & wip at BDC end(3100 qty) by the HG & VC 60 nos and 3040 nos by template ,found All part not ok- Bhuvan
 
3. Process Flow
Process Flow Description
10.RM receiving & inspection 20.Die casting & inspection 30.Fettling & Filing 40.Shot blasting 50.Drilling 60.VMC machining......(Incident station) 70.Air cleaning 80.Impregnation 90.Pin Pressing 100.Leak Testing 110.Final inspection 120.Packing & storage 130.Dispatch
 
4. Process Details
Process / Operation Machining/Grooving
Outsource No
Machine / Cell VMC09/Machining
Machine / Cell No. VMC09/B03
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ToolGroove tool not okGroove tool inspection not doneX
MachineVibration in machine, new machine, New FixturePM check sheet & 4M verified , Found okO
MaterialWrong gradeMTC & LTC verified , Found okO
ManUntrained operator/ inspectorSkill matrix verified & found okO
MethodGroove inspection is not done during FPAFPA report verified & found groove inspection point missingX
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method First peace approval
Check Point at Final Inspection No
Checking Freq. Sampling
Sampling No
Sample Size 0
7. Root Cause Analysis (Occurance)
Why 1 Leakage in Canister
Why 2 Groove O Ring loose
Why 3 Groove width over size
Why 4 Groove tool not ok
Why 5
Root Cause (Occurance) Groove tool not Ok
 
Root Cause Analysis (Outflow)
Why 1 Leakage in Canister
Why 2 Groove O Ring loose
Why 3 Groove width over size
Why 4 Groove width inspection Point miss in FPA report & PDI report
Why 5
Root Cause (Outflow) Groove width inspection Point miss in FPA report
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Occurance1.Quality alert 2. Tool incoming inspection report 3.Set up approval reportAbhay saxena & Akshay02/06/202202/06/2022Completed
Outflow1.OPL 2.OJT 3.Point Add in FPA Report 4.Point add in PDI reportAkshay03/06/202203/06/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 1.1 no`s groove width inspection in every shift(During FPA) by VC in every shift after parting of sample part . 2. 1 no`s groove width inspection in every lot(During PDI) by VC in every lot after parting of sample part .
Inspection Method Instrument
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 1
10. Evidance of Countermeasure
Occurance (Before) No tool Inspection report
156_Occurance_Before.xlsx
Occurance (After) Tool inspection report available
156_Occurance_After.xlsx
Outflow (Before) Groove width inspection Point miss in FPA report & PDI report
156_Outflow_Before.xlsx
Outflow (After) Groove width inspection Point miss added in FPA report & PDI report
156_Outflow_After.xlsx
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant No
 
12. Document Review
Documents ControlPlan, PFMEA, WISOP, AuditCheckSheet, InspCheckSheet
Specify Other Document FPA & PDI report
 
13. Effectiveness Of Action
Reviewed Quantity 1
Reason for submission Found OK