QFR No - 8000789810
Defect Details
NC No. 8000789810
NC Date 02/06/2022
NC Submission Date
Part No. B2GQ03323O
Part Name M/CYL BODY RAW POW.COATED-RE J1C FRONT
Supplier Name & Code 100204-KRISHNA COATING
ETL Plant 1120-ETL K-226/2 Disc Brakes
Defect Details POWDER COATING NOT OK-AFTER100%INSP.DUST,UNCOVER,BUBBLE
 
1. Problem Description
Defect Description Dust and uncover
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 60
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID qualitykrishnaassociates01@gmail.com
Plant Head/CEO Email ID ravikrishnacoating@gmail.com
MD Email ID krishnacoating@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
4448
0
0
0
0
4448
Check Qty
4448
0
0
0
0
4448
NG Qty
125
0
0
0
0
125
 
Scrap 0
Rework 125
Under Deviation 0
Containment Action
before sampling basis Inspection done at inward stage. but currently we start 100 % raw material Inspection at inward inspection stage
 
3. Process Flow
Process Flow Description
Inward -100 % visual inspection - Pretreatment - Drying - Powder coating - Baking - final inspection - packing & dispatch
 
4. Process Details
Process / Operation Powder Coating
Outsource No
Machine / Cell Powder coating line
Machine / Cell No. Powder coating line
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MaterialRusty material , oily ,Rusty material observed at inward stageO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100 %
7. Root Cause Analysis (Occurance)
Why 1 Bubble defect observed
Why 2 White rust observe in master cylinder RE- J1C at inward stage
Why 3 no 100 % visual inspection plan at inward stage
Why 4
Why 5
Root Cause (Occurance) White rusty part observe at inward inspection stage
 
Root Cause Analysis (Outflow)
Why 1 rusty material observed
Why 2 Only inward inspection on sampling basis
Why 3
Why 4
Why 5
Root Cause (Outflow) Rusty Material
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceNow we started 100% visual inspection at inward stageAhok dabhade04/07/202205/07/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 100% visual Inspection at inward stage
Inspection Method Other
Other Inspection Method VIsual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100 %
10. Evidance of Countermeasure
Occurance (Before) only sampling basis inward inspection at inward stage
161_Occurance_Before.pdf
Occurance (After) Now Started 100 % visual inspection at inward stage ( as per sampling plan )
161_Occurance_After.pdf
Outflow (Before) only sampling basis inward inspection at inward stage
161_Outflow_Before.pdf
Outflow (After) Now Started 100 % visual inspection at inward stage ( as per sampling plan
161_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant inward stage
 
12. Document Review
Documents WISOP
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 1360
Reason for submission No rusty found in next 3 lot