QFR No - 8000794827
Defect Details
NC No. 8000794827
NC Date 11/07/2022
NC Submission Date
Part No. F800506307
Part Name STEERING SHAFT WELD ASLY. P/C
Supplier Name & Code 100066-MARATHWADA AUTO COMPO PVT. LTD
ETL Plant 1118-ETL E-92,93 Suspension
Defect Details DIAMETER OVER SIZE-O D O/S LINGTH O/SIZE
 
1. Problem Description
Defect Description Dia/Threading/Total Length Over size
Detection Stage Inprocess
Problem Severity Fitment
NG Quantity 98
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID qaunderbkt@macpl.com
Plant Head/CEO Email ID sdkulkarni@macpl.com
MD Email ID ajit.macpl@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
300
0
0
100
100
500
Check Qty
300
0
0
100
100
500
NG Qty
98
0
0
0
0
98
 
Scrap 98
Rework 0
Under Deviation 0
Containment Action
CHECK 100% JOB AT ETL & MACPL END
 
3. Process Flow
Process Flow Description
NC PARTS FOUND WHILE CNC TURNING.(TOTAL LENGTH FOUND ON HIGHER END)
 
4. Process Details
Process / Operation CNC TURNING
Outsource No
Machine / Cell CNC
Machine / Cell No. CNC
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodTOTAL LENGTH GAUGE WEAR OUTCMM (CMM REPORT FOUND GAUGE WEAROUT)O
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 ST.SHAFT TOTAL LENGTH O/S AT ETL END
Why 2 SKIF AT FINAL INSPECTION OR CAUGE CALIBRATION NOT DONE
Why 3 FINAL INSPECTION MARKING AVAILABLE ON JOB BUT FOUND OVER SIZE AT CUSTOMER
Why 4 TOTAL LENGTH GAUGE FOUND OVER SIZE AT CNC MACHINE .
Why 5
Root Cause (Occurance) TOTAL LENGTH CHECKING GAUGE FOUND OVER SIZE
 
Root Cause Analysis (Outflow)
Why 1 ST.SHAFT TOTAL LENGTH O/S AT ETL END
Why 2 SKIF AT FINAL INSPECTION OR CAUGE CALIBRATION NOT DONE
Why 3 FINAL INSPECTION MARKING AVAILABLE ON JOB BUT FOUND OVER SIZE AT CUSTOMER
Why 4 TOTAL LENGTH GAUGE FOUND OVER SIZE ON FINAL INSPECTION
Why 5
Root Cause (Outflow) TOTAL LENGTH GAUGE FOUND OVER SIZE ON FINAL INSPECTION
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
-------
Type Countermeasure Details Responsibility Target Date Actual Date Status
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details 1.)BEFORE START PRODUCTION WILL CHECK TOTAL LENGTH ON HEIGHT GAUGE.2) TOTAL LENGTH GAUGE CHECK ON CMM EVERY MONTH.
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) CMM GAUGE NOT DONE
197_Occurance_Before.jpg
Occurance (After) GAUGE CORRECTION
197_Occurance_After.jpg
Outflow (Before) CMM GAUGE NOT DONE
197_Outflow_Before.jpg
Outflow (After) GAUGE CORRECTION
197_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant NA
 
12. Document Review
Documents InspCheckSheet
Specify Other Document na
 
13. Effectiveness Of Action
Reviewed Quantity 500
Reason for submission Issue Resolved