QFR No - 8000795258
Defect Details
NC No. 8000795258
NC Date 14/07/2022
NC Submission Date
Part No. F1BF04316M
Part Name OUTER TUBE BUFF LH- K0LA DRUM
Supplier Name & Code 100001-ANANT ENTERPRISES
ETL Plant 1146-ETL Suspension Narasapura
Defect Details DIAMETER OVER SIZE-OIL SEAL AND DUBUSH DIA OVER SIZE
 
1. Problem Description
Defect Description KOPG front fork 2 numbers leakage in dry air leak test in line because of bottom case oil seal diameter ,Du bush diameter over size repeated issue
Detection Stage Inprocess
Problem Severity Function
NG Quantity 2
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID anandkulkarni@anantgroup.co.in
Plant Head/CEO Email ID pramodgosavi@anantgroup.co.in
MD Email ID ashwinjoshi@anantgroup.co.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
2000
0
0
1000
0
3000
Check Qty
2000
0
0
1000
0
3000
NG Qty
1
0
0
3
0
4
 
Scrap 1
Rework 0
Under Deviation 0
Containment Action
100 % SAGRIGATION & DOT IDENTIFICATION ON OIL SEAL ID.
 
3. Process Flow
Process Flow Description
VMC 01 (OP10) -BTA (OP20) - LEAKAGE -VISUAL-BUFFING-PACKIN & DISPATCH
 
4. Process Details
Process / Operation VMC 01(OP-10) 1ST UP
Outsource No
Machine / Cell VMC 01 (OP10)
Machine / Cell No. VMC 01 (OP10)
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ToolBURR CHIP STICK ON ADAPTORVISUALX
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection No
Checking Freq. Sampling
Sampling No
Sample Size 8 / HOUR
7. Root Cause Analysis (Occurance)
Why 1 TOOL RUNOUT MORE
Why 2 BURR STICK ON TOOL ADAPTOR DUE TO THAT TOOL RUNOUT MORE AT TIME OF MACHINING
Why 3 TOOL ADAPTOR PROTECTIVE CAP WORN OUT .
Why 4
Why 5
Root Cause (Occurance) BURR STICK ON TOOL ADAPTOR.
 
Root Cause Analysis (Outflow)
Why 1 TOOL ADAPTOR CAP CHECK POINT NOT ADDRESED IN PREVENTIVE CHECK SHEET.
Why 2 NO AWARENESS ABOUT THIS TYPE OF NG POSSIBILITY.
Why 3
Why 4
Why 5
Root Cause (Outflow) TOOL ADAPTOR CAP CHECK POINT NOT ADDRESED IN PREVENTIVE CHECK SHEET.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowAWARENESS & TRAINING RECORDBHAGYESH KHAIRNAR22/07/202222/07/2022Completed
OccurancePREVENTIVE MAINTAINANCE CHECK SHEET UPDATEMALLAPA DALAVI22/07/202222/07/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details AIR PLUG GAUGE
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection No
Checking Freq. Sampling
Sampling No
Sample Size 8/ HOUR
10. Evidance of Countermeasure
Occurance (Before) PROCESS IMPROVEMENT
199_Occurance_Before.xls
Occurance (After) PROCESS IMPROVEMENT
199_Occurance_After.xls
Outflow (Before) PM CHECK SHEET
199_Outflow_Before.xlsx
Outflow (After) PM CHECK SHEET
199_Outflow_After.xlsx
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant KONA BOTTOM CASE
 
12. Document Review
Documents PMCheckSheet
Specify Other Document PROCESS IMPROVEMENT
 
13. Effectiveness Of Action
Reviewed Quantity 2000
Reason for submission reviewed 2000 numbers found ok