QFR No - 8000802992
Defect Details
NC No. 8000802992
NC Date 06/09/2022
NC Submission Date
Part No. F2GN20502B
Part Name MAIN SPRING
Supplier Name & Code 100952-STUMPP SCHUELE AND SOMAPPA SPR
ETL Plant 1118-ETL E-92,93 Suspension
Defect Details HIGHT O/SIZE.-LINGTH OVER SIZE
 
1. Problem Description
Defect Description Free length found over size by 1 MM.
Detection Stage Inprocess
Problem Severity Function
NG Quantity 66
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID hravikumar@ssssprings.com
Plant Head/CEO Email ID sreenivasulu.k@ssssprings.com
MD Email ID rln@ssssprings.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1000
0
0
0
0
1000
Check Qty
1000
0
0
0
0
1000
NG Qty
66
0
0
0
0
66
 
Scrap 66
Rework 0
Under Deviation 0
Containment Action
After Receipt a complaint 100 % inspection verified to Free Length
 
3. Process Flow
Process Flow Description
Coiling - Tempering-Grinding-Shot Peening - Setting-100% Lo Inspection-2nd Tempering-Final Inspection-Oiling-Packing
 
4. Process Details
Process / Operation 100% Lo Inspection
Outsource No
Machine / Cell FF Cell
Machine / Cell No. FF Cell
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodDue to Initial Stage Free Length not added into Regular WIYesO
 
6. Inspection Method Analysis (Current)
Inspection Method Sp. Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 05
7. Root Cause Analysis (Occurance)
Why 1 Due to Initial Stage Free Length not added into Regular WI
Why 2 This 100% Length Sorting done on 2 Inspection Stage
Why 3 1of the Operator less aware about this Specification
Why 4
Why 5
Root Cause (Occurance) Specification not displayed on Regular inspection Table,
 
Root Cause Analysis (Outflow)
Why 1 During Sample basis Inspection done of 1 Operator
Why 2 Due to 05 No`s Sample inspection done to only 1 opearotor
Why 3
Why 4
Why 5
Root Cause (Outflow) Sample inspection done to Only 1 Opearator
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceInitial Stage Free Length will be added into Regular WIMr. Ishwar Jadhav09/09/202209/09/2022Completed
OutflowSample inspection will be done by QA to each operatorMr. Shivkumar Fartade07/09/202207/09/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Sample inspection will be done by QA to each operator
Inspection Method Sp. Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 02/E OP.
10. Evidance of Countermeasure
Occurance (Before) Due to Initial Stage Free Length not added into Regular WI
242_Occurance_Before.pdf
Occurance (After) Specification not displayed on Regular inspection Table,
242_Occurance_After.pdf
Outflow (Before) During Sample basis Inspection done of 1 Operator
242_Outflow_Before.jpg
Outflow (After) Sample inspection will be done by QA to each operator
242_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant FF Cell
 
12. Document Review
Documents WISOP
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 66
Reason for submission we have checked this lot and found ok.