QFR No - 8000803430
Defect Details
NC No. 8000803430
NC Date 08/09/2022
NC Submission Date
Part No. 520FW04602
Part Name CLUTCH HOUSING FULL FINISHED
Supplier Name & Code 100656-MADHURA DIE CAST PVT.LTD
ETL Plant 1132-ETL K-226/1 TRANSMISSION
Defect Details POROSITY-POROSITY OBSERVED LEVEL L5/L6
 
1. Problem Description
Defect Description POROSITY OBSERVED LEVEL L5/L6
Detection Stage Inprocess
Problem Severity Function
NG Quantity 4
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID madhuradiecast@gmail.com
Plant Head/CEO Email ID madhuradiecast@gmail.com
MD Email ID madhuradiecast@gaikegroup.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
500
0
0
3500
500
4500
Check Qty
500
0
0
3500
500
4500
NG Qty
4
0
0
3500
500
4004
 
Scrap 4004
Rework 0
Under Deviation 0
Containment Action
All Component are hold & rejected at our end. 4000 Nos rejected.
 
3. Process Flow
Process Flow Description
1.Casting 2.fetling 3. CNC 1st Set-up 4.CNC 2nd Set-up 5.Final Inspection.
 
4. Process Details
Process / Operation Casting
Outsource No
Machine / Cell HPDC
Machine / Cell No. HPDC NO.04
5. Problem Analysis
Type Possible Cause Fact Verification Jud
Tool1.3W4S Housing MSI insert gate area got erosion.We checked whether the die is erosion or notX
ToolCooling system of dieCooling system of die found ok conditionO
ToolVenting system of dieDie loading and unloading inspection sheet checked found okO
MachinePlunger velocity 1ST stageVelocity of plunger checked as per process standard sheet foundO
ToolTemperature of dieTemperature of die found as per process sheetO
MachinePlunger velocity is 2nd stageVelocity of plunger checked as per process standard sheet foundO
MachineMulti pressure 3rd stageMulti stage pressure checked as per process standard sheet foundO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method X- Ray test feq less
Check Point at Final Inspection No
Checking Freq. Sampling
Sampling No
Sample Size NA
7. Root Cause Analysis (Occurance)
Why 1 3W4S Housing MSI insert gate area got erosion.
Why 2 Heat zone was created.
Why 3 The heat zone created at the gate area thickness was low 73.25mm.
Why 4
Why 5
Root Cause (Occurance) The heat zone created at the gate area thickness was low 73.25mm.
 
Root Cause Analysis (Outflow)
Why 1 X-ray testing frequency was less.
Why 2 X-ray testing plan not available.
Why 3
Why 4
Why 5
Root Cause (Outflow) X-ray testing frequency was less.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Outflow1. X-ray testing frequency changes once in a year to Quarterly.QA Engineer01/10/202205/10/2022Completed
Occurance1.In 3W4S Housing MSI insert modified at gate area radius is R1 and R3. 2.Material gate area dimension modified up to 75.00mm. 3.Die inspection check sheet is implemented at loading and unloading on machine stage.Production Supervisior PDC12/10/202214/10/2022Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 1. X-ray testing frequency changes once in a year to Quarterly.
Inspection Method Other
Other Inspection Method X-ray Testing
Check Point at Final Inspection No
Checking Freq. Sampling
Sampling No
Sample Size NA
10. Evidance of Countermeasure
Occurance (Before) 1..3W4S Housing MSI insert gate area got erosion. 2.Material entry gate area dimension found 73.25mm against 75.00mm.
249_Occurance_Before.png
Occurance (After) 1.In 3W4S Housing MSI insert modified at gate area radius is R1 and R3 as shown by a green circle. 2.Material gate area dimension modified up to 75.00mm. 3.Porosity level on part found L1/L2
249_Occurance_After.png
Outflow (Before) X-ray testing frequency was less.
249_Outflow_Before.jpg
Outflow (After) X-ray testing frequency changes once in a year to Quarterly.
249_Outflow_After.png
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant K70 Housing Clutch
 
12. Document Review
Documents ControlPlan, PFMEA, AuditCheckSheet
Specify Other Document Testing Plan
 
13. Effectiveness Of Action
Reviewed Quantity 4000
Reason for submission 1)No recurrence of defect phenomenon, 2)X Ray Inspection frequency optimized from once in year to Quarterly