QFR No - 8000807222
Defect Details
NC No. 8000807222
NC Date 08/10/2022
NC Submission Date
Part No. 550DZ05202
Part Name FORK BOLT :PRFH-006
Supplier Name & Code 100189-SANGKAJ STEEL PVT LTD.
ETL Plant 1116-ETL K-120 Suspension
Defect Details DIMN.O/SIZE.-DIM 3.2 OVERSIZE
 
1. Problem Description
Defect Description Groove width oversize concern observed. After allowing segregation 620 nos. observed not OK.
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 620
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID qualityassurance@sangkaj.com
Plant Head/CEO Email ID steel@sangkaj.com
MD Email ID anirudh.2007@hotmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
5000
0
0
1000
1500
7500
Check Qty
5000
0
0
1000
1500
7500
NG Qty
620
0
0
0
0
620
 
Scrap 620
Rework 0
Under Deviation 0
Containment Action
Suspected qty verified at customer end and In-house.
 
3. Process Flow
Process Flow Description
Inward Inspection > Cold Draw > Straightning > Traube > Deburring > Grinding > CNC Turn > Tapping > Thread Rolling > Plating > Final Inspection
 
4. Process Details
Process / Operation CNC
Outsource No
Machine / Cell CNC cell
Machine / Cell No. 25
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MachineVibrations in tool HolderTool holder found looseX
 
6. Inspection Method Analysis (Current)
Inspection Method Sp. Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 5%
7. Root Cause Analysis (Occurance)
Why 1 Groove Dimension o/s
Why 2 Insert viable while machining
Why 3 Insert not tighten properly
Why 4 Insert holder pocket found wear out
Why 5
Root Cause (Occurance) Insert holder pocket found wear out
 
Root Cause Analysis (Outflow)
Why 1 NG Piece not traced in sampling basis
Why 2 sampling frequency found less
Why 3
Why 4
Why 5
Root Cause (Outflow) sampling frequency at FID found less
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceTool holder chnagedMr. Raut Sir10/10/2022Pending
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Sampling frequency increased to 10 %
Inspection Method Sp. Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 10%
10. Evidance of Countermeasure
Occurance (Before) Insert holder pocket found wear out
278_Occurance_Before.pptx
Occurance (After) Tool holder chnaged
278_Occurance_After.pptx
Outflow (Before) sampling frequency at FID found less
278_Outflow_Before.jpeg
Outflow (After) Sampling frequency increased to 10 %
278_Outflow_After.jpeg
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant CNC
 
12. Document Review
Documents InspCheckSheet
Specify Other Document FID Checksheet
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission