QFR No - 8000807947
Defect Details
NC No. 8000807947
NC Date 17/10/2022
NC Submission Date
Part No. S2BG02502B
Part Name BRACKET UN P/C KTEP
Supplier Name & Code 100973-TESMO MOTORCAST PRIVATE LIMITE
ETL Plant 1116-ETL K-120 Suspension
Defect Details THREADING NOT OK-THREADING NOT OK
 
1. Problem Description
Defect Description Bracket KTEP observed with threading not ok concern. In every month major qty. rejected for same.
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 967
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID rkhare@tesmomotorcast.com
Plant Head/CEO Email ID harish.bala@tesmomotorcast.com
MD Email ID svkallani@tesmomotorcast.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
767
0
0
0
0
767
Check Qty
767
0
0
0
0
767
NG Qty
767
0
0
0
0
767
 
Scrap 500
Rework 100
Under Deviation 67
Containment Action
core pin bend issuse
 
3. Process Flow
Process Flow Description
pdc , debering ,remer , vibro ,chamfer ,taping , air claning ,pack
 
4. Process Details
Process / Operation pdc,debering ,remer ,vibro ,chamfer ,taping
Outsource No
Machine / Cell pdc
Machine / Cell No. pdc 250 1
5. Problem Analysis
Type Possible Cause Fact Verification Jud
Toolcore pin bendGaugeO
Materialcore pin hardness not okhardness testing report checkO
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size every hrs
7. Root Cause Analysis (Occurance)
Why 1 Tap not gone up to required depth
Why 2 Tap jam while completing its cycle
Why 3 Hole pin perpendicularity not ok
Why 4 Die core pin bend
Why 5 Pin hardness not as per requirement
Root Cause (Occurance) Core pin hardness not freeze.
 
Root Cause Analysis (Outflow)
Why 1 Tap not gone up to required depth
Why 2 Tap jam while completing its cycle
Why 3 Hole pin perpendicularity not ok
Why 4 Die core pin perpendicularity not ok
Why 5 Perpendicularity not check
Root Cause (Outflow) Core pin Perpendicularity checking frequency not defined.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Outflowhourly pin hole perpendicularity checkingRahul06/07/202325/06/2023Completed
OccurancePin hardness freezeRavi10/07/202326/06/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Perpendicularity checking started on hourly check on PDC
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 1000
10. Evidance of Countermeasure
Occurance (Before) Core pin bend
290_Occurance_Before.jpg
Occurance (After) Due to the pin bend, taping was not done untill the end.
290_Occurance_After.jpg
Outflow (Before) Guaege install
290_Outflow_Before.jpg
Outflow (After) Guaege checking strat
290_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant Pdc 250 t 1 KTEP Bracket
 
12. Document Review
Documents JHCheckSheet, InspCheckSheet
Specify Other Document Pm check sheet, Ins
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission