QFR No - 8000811541
Defect Details
NC No. 8000811541
NC Date 21/11/2022
NC Submission Date
Part No. B2BK04703O
Part Name CALIPER BODY RAW-YAMAHA CBS
Supplier Name & Code 100986-MAP ALLOYS
ETL Plant 1159-ETL E-71 Disc Brakes
Defect Details DENTS & DAMAGES-CASTING DEFECTS DENT & DAMAGE,BLOW HOLE
 
1. Problem Description
Defect Description Damage
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 51
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID vinayak@mapalloys.com
Plant Head/CEO Email ID milind@mapalloys.com
MD Email ID mapalloys3@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
3185
0
0
0
0
3185
Check Qty
3185
0
0
0
0
3185
NG Qty
51
0
0
0
0
51
 
Scrap 51
Rework 0
Under Deviation 0
Containment Action
100% Segregation done and awareness training provided
 
3. Process Flow
Process Flow Description
RM inward-Incoming Inspection-Storage of RM- Melting -Metal treatment-DIE PREPARATION & DIE LOADING- .CASTING -RUNNER/RISER CUTTING - 90.FETTLING/Grinding-HEAT TREATMENT- Heat No.Punching & SHOT BLASTING -FINAL INSPECTION-PACKING -STORE & DISPATCH
 
4. Process Details
Process / Operation 90-FETTLING/Grinding
Outsource No
Machine / Cell 05/02
Machine / Cell No. 05/02
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ManCasting handlingCasting handling evaluateO
ToolHigh point on dieHigh point on die evaluateX
MachineMachine running conditionMachine running condition evaluateO
MethodCasting Hanging on trolleyCasting hanging on trolley evaluateO
MaterialChemical compositionChemical composition verifiedO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 Hard flash at parting line
Why 2 Gap between both halves of die
Why 3 High point on parting surface of die
Why 4 Die blue matching frequency inadequate
Why 5
Root Cause (Occurance) Die blue matching frequency inadequate
 
Root Cause Analysis (Outflow)
Why 1 No awareness of concern person.
Why 2 Limit sample not displayed and no awareness training.
Why 3
Why 4
Why 5
Root Cause (Outflow) Limit sample not displayed and no awareness training.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceDie blue matching frequency changed from 6 months to 4 months for high point removal from die surfaceMr.Anil Dhande15/03/202330/03/2023Completed
OutflowMaterial handling awareness training and limit sample displayed.R.Pandey15/03/202330/03/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 100% visual inspection with dot mark for 3 lots
Inspection Method Other
Other Inspection Method Visually
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) Blue matching frequency inadequate
306_Occurance_Before.xlsx
Occurance (After) Die blue matching frequency changed from 6 months to 4 months for high point removal from die surface
306_Occurance_After.xlsx
Outflow (Before) No limit sample displayed and awareness training about material handling
306_Outflow_Before.xlsx
Outflow (After) Limit sample displayed and awareness training provided
306_Outflow_After.xlsx
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant GDC machine/Yamaha/2
 
12. Document Review
Documents ControlPlan, PFMEA, WISOP
Specify Other Document no
 
13. Effectiveness Of Action
Reviewed Quantity 432
Reason for submission ok ensure