QFR No - 8000817842
Defect Details
NC No. 8000817842
NC Date 20/01/2023
NC Submission Date
Part No. B2BK06823O
Part Name CALIPER BODY-PAINTED - ATHER FR
Supplier Name & Code 206460-TULJA ENTERPRISES
ETL Plant 1120-ETL K-226/2 Disc Brakes
Defect Details PANIT UNCOVER-AFTER 100% INSP. DUST, UNCOVER, ORANGE P
 
1. Problem Description
Defect Description Paint uncover,dust,paint peel off
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 30
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID tuljaenterprises.e124@gmail.com
Plant Head/CEO Email ID info@tulja.in
MD Email ID tuljaenterprises.e124@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
30
0
0
0
0
30
Check Qty
30
0
0
0
0
30
NG Qty
30
0
0
0
0
30
 
Scrap 0
Rework 30
Under Deviation 0
Containment Action
The touch up spray is under development. Once it will be developed, The issue be cured. Currently we are touching it up with existing paint.
 
3. Process Flow
Process Flow Description
Receipt of NG parts - Paint application and NG area - Baking - Visual inspection - Packing - Dispatch
 
4. Process Details
Process / Operation Repainting
Outsource No
Machine / Cell Paint Booth
Machine / Cell No. NA
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ManSensitive ShadeThe shade is sensitive at curved areasX
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method L4 Operator Deployed
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 The component geometry is difficult to cover with electrostatic gun.
Why 2 The shade is sensitive
Why 3 Paint not applied properly
Why 4 Painter coverage was poor at curved area
Why 5 L3 Operator deployed at inspection stage
Root Cause (Occurance) Improper application of paint at curved and deep surface.
 
Root Cause Analysis (Outflow)
Why 1 L3 operator was deployed
Why 2 Inspector did not inspected properly
Why 3 Operator did not inspected the curved and deep surface of the component.
Why 4 Operator did not informed senior inspector
Why 5 Senior operator was not inspecting the parts
Root Cause (Outflow) L3 operator was deployed for inspection
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceConventional gun will used for coverage at deep surface.Operation Head03/02/202303/02/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Additional inspector placed for a month at the inspection stage
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) Uncover
339_Occurance_Before.jpg
Occurance (After) Covered with iwata gun
339_Occurance_After.jpg
Outflow (Before) Uncover
339_Outflow_Before.jpg
Outflow (After) Ok.
339_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant Paint Booth
 
12. Document Review
Documents
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 250
Reason for submission Paint uncover 100% checked found ok