QFR No - 8000819845
Defect Details
NC No. 8000819845
NC Date 09/02/2023
NC Submission Date
Part No. 520FW04702
Part Name CLUTCH HOUSING FULL FINISHED-K70
Supplier Name & Code 100656-MADHURA DIE CAST PVT.LTD
ETL Plant 1132-ETL K-226/1 TRANSMISSION
Defect Details RUN OUT MORE-Ø36 MM BOSS R/O UPTO 0.4 MM
 
1. Problem Description
Defect Description Boss Ø36 mm Run out found Oversize up to 0.45 mm again 0.04 mm (Customer Return Housing Clutch)
Detection Stage Customer End
Problem Severity Fitment
NG Quantity 1
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID madhuradiecast@gmail.com
Plant Head/CEO Email ID madhuradiecast@gmail.com
MD Email ID madhuradiecast@gaikegroup.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
800
0
0
500
1000
2300
Check Qty
800
0
0
500
1000
2300
NG Qty
1
0
0
3
1
5
 
Scrap 5
Rework 0
Under Deviation 0
Containment Action
100% Inspection done at ETL End by dial and mandrel with blue dot marking on OD.
 
3. Process Flow
Process Flow Description
1. Casting 2.fetling 3. CNC 1st Set-up 4. CNC 2nd Set-up 5.Final Inspection.
 
4. Process Details
Process / Operation CNC 2nd Set-up
Outsource No
Machine / Cell CNC CELL
Machine / Cell No. CNC 01
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MachineCenter bolt of Chuck was looseJH Sheet is verify but retightening point not updated in sheet.X
ManUnskilled operator was operating machineLevel -03 operator is operate machine.O
MaterialBurr on clamping areaVerify the component found okO
Toolcomponent was not clamp properly in jawJaw pressure found not ok running conditionX
 
6. Inspection Method Analysis (Current)
Inspection Method Instrument
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 1:50
7. Root Cause Analysis (Occurance)
Why 1 Concentricity Of Outer Diameter 36.00 mm wrt ID 22.0 mm Found 0.4 mm against 0.02 mm.
Why 2 In 2nd setup CNC machining Job gets loose in running.
Why 3 Fixture locator boss was loose.
Why 4
Why 5
Root Cause (Occurance) In machine running condition, the center bolt in the chuck was gets loose.
 
Root Cause Analysis (Outflow)
Why 1 Inspector checking method was sampling basis
Why 2 gauging checking frequency was less
Why 3
Why 4
Why 5
Root Cause (Outflow) gauging checking frequency was less
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowTraining and awareness given to inspector for checking 100% Concentricity Of Outer Diameter 36.00. wrt ID 22.0 With reading on job in micron.QA Engineer10/02/202310/02/2023Completed
OccuranceAdditional tightening arrangement by Grub Screw provided for Centre bolt of locator boss to avoid the centre bolt loose issueProduction Supervisior10/02/202310/03/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Started 100% Concentricity Of Outer Diameter 36.00. wrt ID 22.0 With reading on job in micron.
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) JH Sheet is not updated for Centre bolt retightening
359_Occurance_Before.pdf
Occurance (After) JH Sheet is updated for Centre bolt retightening frequency and method
359_Occurance_After.pdf
Outflow (Before) Concentricity checking frequency is sample basis.
359_Outflow_Before.pdf
Outflow (After) Concentricity checking frequency change sample to 100% and reading mentioned on part.
359_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant CLUTCH HOUSING FULL FINISHED-3W4S
 
12. Document Review
Documents ControlPlan, JHCheckSheet, InspCheckSheet
Specify Other Document NO
 
13. Effectiveness Of Action
Reviewed Quantity 2000
Reason for submission OK