QFR No - 8000825247
Defect Details
NC No. 8000825247
NC Date 02/04/2023
NC Submission Date
Part No. F2HB06910M
Part Name OUTER TUBE ANODISED - Ø48 690 SMC
Supplier Name & Code 100975-KRISHNA ASSOCIATES
ETL Plant 1118-ETL E-92,93 Suspension
Defect Details SHADE VARIATION-SHADE VERIATION
 
1. Problem Description
Defect Description Shade variation found on 690 SMC Outer tube
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 201
Is Defect Repeatative? No
Defect Sketch / Photo 0jb0exe3dv3vs0e5m2na4cnq.jpg
Supplier Communication Details
Quality Head Email ID qualitykrishnaassociates01@gmail.com
Plant Head/CEO Email ID ravikrishnacoating@gmail.com
MD Email ID krishnacoating@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
201
0
0
0
0
201
Check Qty
201
0
0
0
0
201
NG Qty
201
0
0
0
0
201
 
Scrap 201
Rework 0
Under Deviation 0
Containment Action
checkpoint added in final inspection sheet OPL Displayed at final inspection stage
 
3. Process Flow
Process Flow Description
Pre-treatment - anodizing -Coloring - Sealing- Inspection - packing -Dispatch
 
4. Process Details
Process / Operation Anodizing
Outsource No
Machine / Cell Anodizing Line
Machine / Cell No. 2
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MachineFaulty timercross checkedO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 Not proper cleaning in water rinse
Why 2 Inadequate time in water rinse
Why 3 Water rinse timer faulty
Why 4 .
Why 5 .
Root Cause (Occurance) Part not cleaned properly in water rinse tank due to timer of water rinse tank malfunction
 
Root Cause Analysis (Outflow)
Why 1 Defective Sample not displayed at final inspection
Why 2 Inspector Not aware about issue
Why 3 Checking skipped from inspector
Why 4 .
Why 5 .
Root Cause (Outflow) Defective sample not displayed at final inspection stage, Inspector Not aware about issue
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceTimer Controller replacedMaintenance02/04/202302/04/2023Completed
OutflowNG part Not displayed at inspection stageQA03/04/202303/04/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details no
Inspection Method Other
Other Inspection Method OPL Displayed
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) Faulty Timer
397_Occurance_Before.jpg
Occurance (After) Timer changed
397_Occurance_After.jpg
Outflow (Before) Before inspection SOP
397_Outflow_Before.pdf
Outflow (After) Updated Inspection SOP Displayed & One Point lesson(OPL) Displayed at final inspection stage
397_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant Timer
 
12. Document Review
Documents PMCheckSheet, InspCheckSheet
Specify Other Document OPL
 
13. Effectiveness Of Action
Reviewed Quantity 1600
Reason for submission All part found ok as per requirement