QFR No - 8000825772
Defect Details
NC No. 8000825772
NC Date 07/04/2023
NC Submission Date
Part No. F2GN12502B
Part Name MAIN SPRING J1A & J1D
Supplier Name & Code 101225-HELICAL SPRINGS
ETL Plant 1117-ETL K-228/9 Suspension
Defect Details NOT AS PER SPECIFICATION-SQUARENESS FOUND NOT OK
 
1. Problem Description
Defect Description Squareness found 2 mm against the spec of 1 mm
Detection Stage Receipt
Problem Severity Function
NG Quantity 483
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID amit.patel@helicalsprings.in
Plant Head/CEO Email ID shaikhmoin@helicalsprings.in
MD Email ID ataneja@helicalsprings.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
6448
0
0
0
0
6448
Check Qty
6448
0
0
0
0
6448
NG Qty
448
0
0
0
0
448
 
Scrap 0
Rework 100
Under Deviation 0
Containment Action
segregate all material at customer end.
 
3. Process Flow
Process Flow Description
Raw Material > Coiling > Stress Relieving - 1 > End Grinding > Shot peening > Scragging > Length, OD & Wavyness Checking > Stress Relieving -2 > Surface Finish Oiling > PDI > Packing & Dispatch.
 
4. Process Details
Process / Operation Grinding Operation
Outsource No
Machine / Cell Grinding Machine
Machine / Cell No. L4G1
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodGrinding Plate Misalignment.Grinding Plate alignment not checkedX
MethodWheel dressing not followed as per defined frequencyWheel dressing done as per the defined frequencyO
MaterialAs per DrawingRMTC checked found okO
MachineHerdonFound okO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method By Spring Standing
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 5
7. Root Cause Analysis (Occurance)
Why 1 End Coil Squareness Out of Spec.
Why 2 Spring not loaded straight in Grinding plate
Why 3 Grinding plate position not ok
Why 4 Holes in layer wise Grinding plates not aligned with respect to each other
Why 5 Alignment of holes of three plates checked with insertion of spring
Root Cause (Occurance) No robust method to check the alignment of holes of three plates
 
Root Cause Analysis (Outflow)
Why 1 End Coil Squareness Out of Spec.
Why 2 Not arrested in inspection
Why 3 Inspection done on sampling basis
Why 4 No 100% inspection defined
Why 5
Root Cause (Outflow) No 100% inspection defined
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Outflow100% inspection of springs by making the springs stand on surfaceProd. And Quality25/03/202325/03/2023Completed
Occurance1.Alignment of grinding plates holes ensured with the help of rod positioned between grinding plates. [OPL ADDED] 2. Check point of alignment of grinding plates added in grinding setup approval. 3.OPL displayed at Grinding 4.Training provided to the operator and recorded the sameProd. And Quality25/03/202325/03/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 100% inspection of springs by making the springs stand on surface
Inspection Method Other
Other Inspection Method By Spring Standing
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 5
10. Evidance of Countermeasure
Occurance (Before) Alignment of grinding plates holes ensured with the help of spring insertion in grinding holes
398_Occurance_Before.pdf
Occurance (After) Alignment of grinding plates holes ensured with the help of rod positioned between grinding plates.
398_Occurance_After.pdf
Outflow (Before) Sampling Inspection
398_Outflow_Before.pdf
Outflow (After) 100 % inspection by making spring stand
398_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant similar model
 
12. Document Review
Documents PFMEA, InspCheckSheet
Specify Other Document setup report
 
13. Effectiveness Of Action
Reviewed Quantity 300
Reason for submission Verified next 3 lot and found ok