QFR No - 8000825878
Defect Details
NC No. 8000825878
NC Date 10/04/2023
NC Submission Date
Part No. B2HF03624O
Part Name MCYL PISTON ANODISED-Ø12,K2 FRONT
Supplier Name & Code 100505-A B AUTOCOMPONENTS
ETL Plant 1120-ETL K-226/2 Disc Brakes
Defect Details HIGHT O/SIZE.-EXCESS TIP AT TOP SIDE OF PISTON
 
1. Problem Description
Defect Description Loose ring observed in part
Detection Stage Receipt
Problem Severity Function
NG Quantity 4
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID headqaabauto@gmail.com
Plant Head/CEO Email ID kamalabautocomponent@gmail.com
MD Email ID abautocomponent@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1000
0
0
0
2000
3000
Check Qty
1000
0
0
0
2000
3000
NG Qty
4
0
0
0
0
4
 
Scrap 4
Rework 0
Under Deviation 0
Containment Action
Available 2000nos verified at AB.
 
3. Process Flow
Process Flow Description
RM - Turning - Tip grinding - Inspection - Anodizing - Final inspection - PDIR - Dispatch.
 
4. Process Details
Process / Operation Turning
Outsource No
Machine / Cell Master Piston Cell
Machine / Cell No. Master Piston Cell
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MaterialNilRM OK as per MTCO
ManNo manual intervention in this problemNo manual interventionO
MethodYesSome parts we are gettingX
ToolNilTool okO
MachineNilMachine found ok as per check sheet.O
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 Tip & Ring found in parts.
Why 2 Generating in the process
Why 3
Why 4
Why 5
Root Cause (Occurance) Process Problem
 
Root Cause Analysis (Outflow)
Why 1 Tip & Ring found in parts.
Why 2 Skipped from the inspection
Why 3 New Inspector.
Why 4
Why 5
Root Cause (Outflow) New inspector.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Outflow1. Awareness given to the inspectors at final inspection. 2. Defect photos available in defect matrixHarshith22/04/202322/04/2023Completed
Occurance1. Process improvement taken place but still not controlled 100%, 2. Manual tip grinding doing.Sudhir25/04/202325/04/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details Awareness given to inspectors.
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before)
Occurance (After)
Outflow (Before)
Outflow (After)
 
11. Horizontal Deployment
Horizontal Deployment Required
Applicable Machine / Model / Plant
 
12. Document Review
Documents
Specify Other Document
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission