QFR No - 8000826277
Defect Details
NC No. | 8000826277 |
NC Date | 14/04/2023 |
NC Submission Date | |
Part No. | S2HT11707B |
Part Name | OUTER SPRING POWDER COATED |
Supplier Name & Code | 101225-HELICAL SPRINGS |
ETL Plant | 1118-ETL E-92,93 Suspension |
Defect Details | BEND-BEND |
1. Problem Description
Defect Description | Taper Coil Observed Bend |
Detection Stage | Inprocess |
Problem Severity | Fitment |
NG Quantity | 264 |
Is Defect Repeatative? | No |
Defect Sketch / Photo |
Supplier Communication Details
Quality Head Email ID | amitpatel.24@rediffmail.com |
Plant Head/CEO Email ID | shaikhmoin@helicalsprings.in |
MD Email ID | ataneja@helicalsprings.in |
2. Stock Details & action taken for NG parts
Location | ETL End | Warehouse | Transit | Supplier FG | Supplier WIP | Total |
---|---|---|---|---|---|---|
Total Qty |
14160
|
0
|
0
|
0
|
300
|
14460
|
Check Qty |
14160
|
0
|
0
|
0
|
300
|
14460
|
NG Qty |
395
|
0
|
0
|
0
|
0
|
395
|
Scrap | 395 |
Rework | 0 |
Under Deviation | 0 |
Containment Action |
---|
100% Segregation done |
3. Process Flow
Process Flow Description |
---|
As per PFD |
4. Process Details
Process / Operation | Coling |
Outsource | No |
Machine / Cell | -- |
Machine / Cell No. | -- |
5. Problem Analysis
Type | Possible Cause | Fact Verification | Jud |
---|---|---|---|
Method | No concentricity check at coiling | No method to check concentricity at coiling | O |
6. Inspection Method Analysis (Current)
Inspection Method | Other |
Other Inspection Method | VIsual |
Check Point at Final Inspection | No |
Checking Freq. | 100% |
Sampling | No |
Sample Size | 100 |
7. Root Cause Analysis (Occurance)
Why 1 | Spring bend at small ID side |
Why 2 | Taper coil at small ID shift |
Why 3 | Concentricity of spring ID not Ok |
Why 4 | Concentricity approved by visual Check |
Why 5 | No Concentricity Gauge Defined at coiling |
Root Cause (Occurance) | No Concentricity Gauge Defined at coiling |
Root Cause Analysis (Outflow)
Why 1 | Bend Spring Not arrested in inspection |
Why 2 | No Check point of Spring Concentricity. |
Why 3 | |
Why 4 | |
Why 5 | |
Root Cause (Outflow) | No Check point of Spring Concentricity. |
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type | Countermeasure Details | Responsibility | Target Date | Actual Date | Status |
---|---|---|---|---|---|
Outflow | Concentricity Checking Gauge during Dock Audit | AP | 14/04/2023 | 14/04/2023 | Completed |
Occurance | Concentricity Checking Gauge introduced at coiling | NK | 14/04/2023 | 17/04/2023 | Completed |
9. Inspection Method After Customer Complaint
Change In Inspection System | Yes |
Change Details | Concentricity Checking Gauge during Dock Audit |
Inspection Method | Gauge |
Other Inspection Method | |
Check Point at Final Inspection | Yes |
Checking Freq. | Sampling |
Sampling | No |
Sample Size | 5 |
10. Evidance of Countermeasure
Occurance (Before) |
No Gauge introduced before 412_Occurance_Before.pdf |
Occurance (After) |
Concentricity gauge Introduced 412_Occurance_After.pdf |
Outflow (Before) |
No Gauge introduced before 412_Outflow_Before.pdf |
Outflow (After) |
Concentricity gauge Introduced 412_Outflow_After.pdf |
11. Horizontal Deployment
Horizontal Deployment Required | No |
Applicable Machine / Model / Plant | K1 Old |
12. Document Review
Documents | PFMEA, WISOP, InspCheckSheet |
Specify Other Document | OPL |
13. Effectiveness Of Action
Reviewed Quantity | 1000 |
Reason for submission | No Defect Reported after Action |