QFR No - 8000828496
Defect Details
NC No. 8000828496
NC Date 09/05/2023
NC Submission Date
Part No. F2GN22102B
Part Name MAIN SPRING - J1C2 FF
Supplier Name & Code 101225-HELICAL SPRINGS
ETL Plant 1117-ETL K-228/9 Suspension
Defect Details NOT AS PER SPECIFICATION-OVERALL LENGTH OVERSIZE
 
1. Problem Description
Defect Description Overall length found oversize by 7 mm.
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 143
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID amit.patel@helicalsprings.com
Plant Head/CEO Email ID shaikhmoin@helicalsprings.in
MD Email ID ataneja@helicalsprings.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
3000
0
0
5000
0
8000
Check Qty
3000
0
0
5000
0
8000
NG Qty
143
0
0
0
0
143
 
Scrap 0
Rework 143
Under Deviation 0
Containment Action
Segregation of Total stock completed
 
3. Process Flow
Process Flow Description
RM receipt - Coiling- SR1-Grinding- Shot peening- scragging- 100% length checking- SR2-oiling-PDI
 
4. Process Details
Process / Operation 100% Checking
Outsource No
Machine / Cell Length Checking
Machine / Cell No. 1
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodRework sample mixonly one yellow bin usedO
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 5/lot
7. Root Cause Analysis (Occurance)
Why 1 Length oversize observed at customer end
Why 2 Length oversize sample mix with Ok lot
Why 3 length Oversize material kept in green bin
Why 4 yellow bin at use was only 1
Why 5 No extra yellow bin used by operator for more qty of RW
Root Cause (Occurance) No extra yellow bin used by operator for more qty of RW
 
Root Cause Analysis (Outflow)
Why 1 Length oversize observed at customer end
Why 2 Mix up of RW samples occurred after 100% sorting
Why 3 -
Why 4 -
Why 5 -
Root Cause (Outflow) Mix up of RW samples occurred after 100% sorting
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceOPL displayed for usage of yellow bins only for RWProd29/04/202329/04/2023Completed
OutflowOPL displayed for usage of yellow bins only for RW. Training providedProd29/04/202329/04/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details no
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100
10. Evidance of Countermeasure
Occurance (Before) Operator used Green bin to keep extra RW material
446_Occurance_Before.pdf
Occurance (After) OPL displayed for using only Yellow bin
446_Occurance_After.pdf
Outflow (Before) Operator used Green bin to keep extra RW material
446_Outflow_Before.pdf
Outflow (After) Training Provided to operator
446_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant All Items
 
12. Document Review
Documents AuditCheckSheet
Specify Other Document OPL
 
13. Effectiveness Of Action
Reviewed Quantity 300
Reason for submission ok