QFR No - 8000833966
Defect Details
NC No. 8000833966
NC Date 23/06/2023
NC Submission Date
Part No. F2FA15933M
Part Name FORK PIPE MACHINED (K19 DRUM FF)
Supplier Name & Code 100634-TATA STEEL LIMITED
ETL Plant 1126-ETL Pantnagar
Defect Details DIMN.U/SIZE.-DIM. U/D OB 8.5 AGINST 11MM
 
1. Problem Description
Defect Description Fitment Issue : DIMENSION UNDERSIZE.-OBSERVATION 8.50 MM AGAINST 11.00 MM
Detection Stage Inprocess
Problem Severity Fitment
NG Quantity 215
Is Defect Repeatative? Yes
Defect Sketch / Photo ri0exybddt0kzupjmkggm1ck.docx
Supplier Communication Details
Quality Head Email ID bipldholpur@gmail.com
Plant Head/CEO Email ID harsh.pareek@tatasteel.com
MD Email ID Praveens@tatasteel.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
500
0
0
0
200
700
Check Qty
500
0
0
0
200
700
NG Qty
100
0
0
0
15
115
 
Scrap 15
Rework 0
Under Deviation 0
Containment Action
100 % Inspection done at ETL and next lots to be supplied only after 100% inspection at TSL end.
 
3. Process Flow
Process Flow Description
CNC 1st set up (Threading)
 
4. Process Details
Process / Operation CNC Turning
Outsource No
Machine / Cell CNC- Marshall
Machine / Cell No. 03
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MaterialNo Probable root cause related to materialNo Probable root cause related to materialO
ToolNo Probable root cause related to materialNo Probable root cause related to materialO
ManNo Probable root cause related to materialNo Probable root cause related to materialO
MachineHydraullic Pressure VariationHydraulic Oil, Internal Leakage in chuck CylinderX
MethodLot of sampling was smallDue to small lot size , Defected Pieces can SkipX
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 05
7. Root Cause Analysis (Occurance)
Why 1 Fork pipe K19 of Dim under size
Why 2 Hydraullic Oil Presssure Varry
Why 3 Hydraulic Oil, Internal Leakage in chuck Cylinder
Why 4 No Check Point in System
Why 5
Root Cause (Occurance) Hydraullic oil Internally leakage in Chuck Cylinder due to this Pressure Varry
 
Root Cause Analysis (Outflow)
Why 1 Fork pipe K19 of Dim under size
Why 2 Not detected in, Inhouse Inspection
Why 3 Lot of sampling was small ( 5 Pcs Hourly)
Why 4
Why 5
Root Cause (Outflow) Lot of sampling was small ( 5 Pcs Hourly)
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Occurance1- check Point added in daily Maintenance check sheetQA12/05/202312/05/2023Completed
Outflow1.-Lot of Sampling Increases From 5 pcs Hourly to 25 Pcs Hourly 2- Given OPL On this ProblemQA Supervisor12/05/202312/05/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Lot of Sampling Increases ( From 5 pcs Hourly to 25 Pcs Hourly )
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 05
10. Evidance of Countermeasure
Occurance (Before) NO CHECK POINT DAILY PM CHECKLIST
492_Occurance_Before.jpg
Occurance (After) CHECK POINT ADDED INDAILY PM CHECKLIST
492_Occurance_After.jpg
Outflow (Before) 05 Pcs Checked Hourly
492_Outflow_Before.jpg
Outflow (After) 25 Pcs Checked Hourly
492_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant ALL CNC MACHINE
 
12. Document Review
Documents ControlPlan, PMCheckSheet
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 2000
Reason for submission OK