QFR No - 8000858545
Defect Details
NC No. 8000858545
NC Date 13/01/2024
NC Submission Date
Part No. B2BK01723O
Part Name CALIPER BODY POWDER COATING -AVENGER
Supplier Name & Code 100204-KRISHNA COATING
ETL Plant 1120-ETL K-226/2 Disc Brakes
Defect Details POWDER COATING NOT OK-PART REJECTED AFTER 100% INSPECTION AT E
 
1. Problem Description
Defect Description POWDER COATING NOT OK
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 192
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID qualitykrishnaassociates01@gmail.com
Plant Head/CEO Email ID ravikrishnacoating@gmail.com
MD Email ID krishnacoating@gmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
3460
0
0
0
0
3460
Check Qty
3460
0
0
0
0
3460
NG Qty
192
0
0
0
0
192
 
Scrap 0
Rework 192
Under Deviation 0
Containment Action
Uncover issue found. After inspection we found Venturi in powder coating gun defective i.e. damaged venturi. We replaced defective venturi with new one. After venturi replacement uncover issue was not observed.
 
3. Process Flow
Process Flow Description
Inward - Pretreatment - Drying - powder Coating- Baking- Final Inspection - dispatch.
 
4. Process Details
Process / Operation Powder Coating
Outsource No
Machine / Cell Powder Coating Line
Machine / Cell No. Powder Coating Line
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MachinePowder Coating Gun defectVenturi in powder coating gun found damagedO
ManInconsistent powder coating by operatorOperator found doing Powder coating okX
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 Uncover issue observed in Caliper Body.
Why 2 Powder Gun not proper check for powder coating process
Why 3 Powder flow not proper on the component
Why 4 Defective venturi observed in Powder coating Gun
Why 5
Root Cause (Occurance) Defective Venturi observed in Coating Gun
 
Root Cause Analysis (Outflow)
Why 1 Uncover issue observed due to damaged coating Gun Venturi
Why 2 Coating Gun venturi not checked on regular basis
Why 3 Improper gun cleaning
Why 4 Operator was unaware about proper gun cleaning
Why 5
Root Cause (Outflow) Coating Gun venturi not checked on regular basis
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowTraining provided to operator on gun checking and cleaningsupervisor15/01/202414/01/2024Completed
OccuranceDamaged Venturi replaced with new one.Supervisor15/01/202414/01/2024Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details No change
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100% a lot
10. Evidance of Countermeasure
Occurance (Before) Damaged Venturi found as shown in attachment
634_Occurance_Before.jpg
Occurance (After) New Venturi replaced with old one which was damaged
634_Occurance_After.jpg
Outflow (Before) Gun Venturi checking was doing once per day
634_Outflow_Before.jpg
Outflow (After) Gun Venturi Checking daily twice.
634_Outflow_After.jpg
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant Al powder coating Guns
 
12. Document Review
Documents
Specify Other Document None
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission