QFR No - 8000865072
Defect Details
NC No. 8000865072
NC Date 29/02/2024
NC Submission Date
Part No. S2AB00512B
Part Name ADJUSTER PLATED
Supplier Name & Code 100782-NICE STEEL INDUSTRIES
ETL Plant 1143-ETL Suspension Halol, Vadodara
Defect Details PLATING NOT OK-PLATING PEEL OFF
 
1. Problem Description
Defect Description Plating Peel off found in adjuster
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 7
Is Defect Repeatative? Yes
Defect Sketch / Photo 3iisml0gioq3mxwcs2srfye1.jpg
Supplier Communication Details
Quality Head Email ID ppc.nice@batragroup.biz
Plant Head/CEO Email ID ho.nice@batragroup.biz
MD Email ID hitesh@batragroup.biz
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1000
1000
2000
2000
1000
7000
Check Qty
1000
1000
2000
2000
1000
7000
NG Qty
1
1
0
2
0
4
 
Scrap 4
Rework 0
Under Deviation 0
Containment Action
All material segregated
 
3. Process Flow
Process Flow Description
10 RECEIVING INSPECTION 20 STORAGE 30 BLANKING 40 1st BENDING ( `U` BENDING) 50 FINAL BENDING ( ROUNDING ) 60 MIG WELDING 70 FLAIRING 80 ID SIZING 90 SIDE GRINDING 100 BROACHING 110 SINGLE GROOVE MATCHING 120 HEAD GRINDING 130 OUTSIDE MOVEMENT FOR PLATING 140 STORAGE & RQC INSP. OF PLATED MATERIAL 150 FINAL INSPECTION 160 PACKING & DISPATCH TO CUSTOMER
 
4. Process Details
Process / Operation Plating
Outsource Yes
Machine / Cell Semi Nickle drug out process
Machine / Cell No. Semi Nickle drug out
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodSemi bright drug out water level lowWater level checked and foundX
MethodProcess was not followedAll process checked and found implementeddO
MachineLow capacity tankSemi bright drug out level was lowX
ToolWrong jig/ hanger usedHanger checked and found okO
ManUnskilled manpowerSkilled manpower available and skill matrix verifiedO
MaterialWrong chemical usedAll chemical checked as per TDS data sheet and found OKO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method File test
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 5 pcs each
7. Root Cause Analysis (Occurance)
Why 1 Peel off
Why 2 Part peel off from bright layer
Why 3 Bright layer was not bond on part
Why 4 Semi bright layer was oxidize
Why 5 Part was not completely in the DM water during semi bright drug out due to Semi Bright drug out water level was low
Root Cause (Occurance) Part was not completely in the DM water during semi bright drug out due to Semi Bright drug out water level was low
 
Root Cause Analysis (Outflow)
Why 1 Defective part passed at customer end
Why 2 Defective part not detected
Why 3 Later peel-off problem generated in part
Why 4
Why 5
Root Cause (Outflow) Later peel-off problem generated in part
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowTraining provided to allVeekay10/03/202420/03/2024Completed
OccuranceSemi Bright drug out water level increasedVeekay12/03/202420/03/2024Completed
OutflowFile test frequency revisedVeekay06/03/202420/03/2024Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details File test frequency revised .
Inspection Method Other
Other Inspection Method File test frequency
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 20 per lot
10. Evidance of Countermeasure
Occurance (Before) Water level was low at semi bright drug out
693_Occurance_Before.pptx
Occurance (After) Water level increased at semi bright drug out
693_Occurance_After.pdf
Outflow (Before) File test done in 5 pcs each lot
693_Outflow_Before.png
Outflow (After) File test done 20 pcs each lot
693_Outflow_After.png
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant Adjuster HF delux
 
12. Document Review
Documents ControlPlan, PFMEA
Specify Other Document OPL
 
13. Effectiveness Of Action
Reviewed Quantity 100
Reason for submission OK