QFR No - 8000873537
Defect Details
NC No. | 8000873537 |
NC Date | 06/05/2024 |
NC Submission Date | |
Part No. | F2DZ15510B |
Part Name | FORK BOLT -ACJA FF |
Supplier Name & Code | 100505-A B AUTOCOMPONENTS |
ETL Plant | 1117-ETL K-228/9 Suspension |
Defect Details | NOT AS PER SPECIFICATION-MIX-UP |
1. Problem Description
Defect Description | Mix-up |
Detection Stage | Inprocess |
Problem Severity | Fitment |
NG Quantity | 93 |
Is Defect Repeatative? | Yes |
Defect Sketch / Photo |
Supplier Communication Details
Quality Head Email ID | headqaabauto@gmail.com |
Plant Head/CEO Email ID | kamalabautocomponent@gmail.com |
MD Email ID | abautocomponent@gmail.com |
2. Stock Details & action taken for NG parts
Location | ETL End | Warehouse | Transit | Supplier FG | Supplier WIP | Total |
---|---|---|---|---|---|---|
Total Qty |
500
|
0
|
0
|
300
|
0
|
800
|
Check Qty |
500
|
0
|
0
|
300
|
0
|
800
|
NG Qty |
93
|
0
|
0
|
0
|
0
|
93
|
Scrap | 0 |
Rework | 93 |
Under Deviation | 0 |
Containment Action |
---|
Not an regular production, Existing FG verified and segregated. |
3. Process Flow
Process Flow Description |
---|
RM inward-Cutting-Turining-Milling-Final quality-Dispatch |
4. Process Details
Process / Operation | Turning & Milling |
Outsource | No |
Machine / Cell | CNC & VMC |
Machine / Cell No. | CNC20 & VMC2 |
5. Problem Analysis
Type | Possible Cause | Fact Verification | Jud |
---|---|---|---|
Method | Similar part production | 13510 & 15510 same time FG | O |
Man | Unaware & not inspected | Similarity in visual, only length got vary. | O |
Tool | Tool offset error | Diffrent parts | O |
Machine | Mixup in the work station | Same trays used | O |
Material | Same Grade material issued | Same material | O |
6. Inspection Method Analysis (Current)
Inspection Method | Instrument |
Other Inspection Method | |
Check Point at Final Inspection | Yes |
Checking Freq. | Sampling |
Sampling | No |
Sample Size | 1-100 |
7. Root Cause Analysis (Occurance)
Why 1 | NOT AS PER SPECIFICATION-MIX-UP |
Why 2 | Both Regular (F2DZ15510B) & Development part (F2DZ12810B) Anodizing done same location. |
Why 3 | As per customer demand Anodizing done the regular part as well as development part. |
Why 4 | For regular parts dispatch as per the schedule, during development stage Only 5 to 10 samples are dispatched, Balance parts are sent it later. |
Why 5 | As per customer requirement. |
Root Cause (Occurance) | Parts mix up happened during Anodizing stage. |
Root Cause Analysis (Outflow)
Why 1 | NOT AS PER SPECIFICATION-MIX-UP |
Why 2 | Both Regular (F2DZ15510B) & Development parts (F2DZ12810B) are kept at final inspection area. |
Why 3 | Before dispatching final inspection to be done. |
Why 4 | As per ISO / IATF standard requirement. |
Why 5 | To supply the defect free products. |
Root Cause (Outflow) | Due to lack of knowledge & confusion parts got mixed up. |
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type | Countermeasure Details | Responsibility | Target Date | Actual Date | Status |
---|---|---|---|---|---|
Occurance | Plan the diffrent interval for machining. | Planning | 20/05/2024 | 10/05/2024 | Completed |
Outflow | Plan the dedicated person to pack the FG`s | Quality head | 20/05/2024 | 10/05/2024 | Completed |
9. Inspection Method After Customer Complaint
Change In Inspection System | Yes |
Change Details | If similarity in visual, Before packing verify the diameter and length of the parts. |
Inspection Method | Gauge |
Other Inspection Method | |
Check Point at Final Inspection | Yes |
Checking Freq. | 100% |
Sampling | No |
Sample Size | 100% |
10. Evidance of Countermeasure
Occurance (Before) |
Machine Plan similar parts same intervals 789_Occurance_Before.xlsx |
Occurance (After) |
Machine plan deffrent intervals. 789_Occurance_After.xlsx |
Outflow (Before) |
Without part Weight . 789_Outflow_Before.xlsx |
Outflow (After) |
With part weight.CP AND FMEA UPDATED 789_Outflow_After.xlsx |
11. Horizontal Deployment
Horizontal Deployment Required | No |
Applicable Machine / Model / Plant | N/A |
12. Document Review
Documents | ControlPlan, PFMEA |
Specify Other Document | N/A |
13. Effectiveness Of Action
Reviewed Quantity | 70 |
Reason for submission | Root cause analysis can do better |