QFR No - 8000877822
Defect Details
NC No. 8000877822
NC Date 11/06/2024
NC Submission Date
Part No. F2DZ03112B
Part Name FORK BOLT
Supplier Name & Code 101263-SINGLA PRECISION SCREWS
ETL Plant 1117-ETL K-228/9 Suspension
Defect Details NOT AS PER SPECIFICATION-UNCOVER, PEEL OFF, DAMAGE
 
1. Problem Description
Defect Description PEEL OFF
Detection Stage Inprocess
Problem Severity Aesthetic
NG Quantity 1
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID quality@singlaprecision.com
Plant Head/CEO Email ID quality@singlaprecision.com
MD Email ID aditya@singlaprecision.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1040
0
0
0
0
1040
Check Qty
1040
0
0
0
0
1040
NG Qty
1
0
0
0
0
1
 
Scrap 1
Rework 0
Under Deviation 0
Containment Action
100% SEGGRATION CUSTOMER END AND OUR END
 
3. Process Flow
Process Flow Description
RAW MATERIAL +PART-OFF CENTER+FORGING +CNC OPERATION IST +CNC OPERATION 2ND+ROLLING+FINAL INSPECTION +PACKING +SURFACE TRATMENT +FINAL INSPECTION+PACKING
 
4. Process Details
Process / Operation PLATING
Outsource Yes
Machine / Cell TANK NO
Machine / Cell No. 01
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MachineIncorrect temperature and pH levels in the bath can affect the quality of the plating.Validated and Found Incorrect temperatureX
MaterialOILY MATERIAL USE ON PLATING PROCESSVALIDATION AND FOUND NO OILYO
ManUNAWARENESS OF OPERATORVALIDATION AND FOUND OPERATOR SKILL LEVEL OKO
MethodVisual Inspection not effectiveValidation and found okO
ToolN/AN/AO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 NOT AS PER SPECIFICATION-UNCOVER, PEEL OFF, DAMAGE
Why 2 incorrect temperature, current density, or plating time.
Why 3 Incorrect current density can cause uneven plating thickness.
Why 4 Daily not Ensure current density during the electroplating process.
Why 5
Root Cause (Occurance) Incorrect temperature, current density, or plating time.
 
Root Cause Analysis (Outflow)
Why 1 NOT AS PER SPECIFICATION-UNCOVER, PEEL OFF, DAMAGE
Why 2 No any checked Quality Gate Available After plating
Why 3 only sampling plan according checked only final inspection area
Why 4 Inspection not fix on plated part
Why 5 low skill inspector checked this lot
Root Cause (Outflow) No any checked Quality Gate Available After plating
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceDaily temperature check sheet prepared and control plan add plating parameterMr Ganesh MAURYA20/06/202421/06/2024Completed
Outflowinspection table arrange near plating area after plating part check 100%Mr Ganesh maurya20/06/202420/06/2024Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System No
Change Details no change
Inspection Method Other
Other Inspection Method visual 100%
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size Sample Siz
10. Evidance of Countermeasure
Occurance (Before) PM CHECK SHEET NOT UPDATE
848_Occurance_Before.pdf
Occurance (After) After PM CHECK SHEET UPDATE
848_Occurance_After.pdf
Outflow (Before) No any checked Quality Gate Available After plating
848_Outflow_Before.xlsx
Outflow (After) Plating part after currying inspection table provide
848_Outflow_After.xlsx
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant PLATING TANK 3 NO
 
12. Document Review
Documents JHCheckSheet
Specify Other Document PFD
 
13. Effectiveness Of Action
Reviewed Quantity 50
Reason for submission 5. Problem Analysis - Need all 4M