QFR No - 8000893366
Defect Details
NC No. | 8000893366 |
NC Date | 27/09/2024 |
NC Submission Date | |
Part No. | S2DA00907O |
Part Name | TOP SPRING LOCATOR |
Supplier Name & Code | 100161-PREMIER ENGINEERS |
ETL Plant | 1118-ETL E-92,93 Suspension |
Defect Details | POWDER COATING NOT OK-POWDER COATING PEEL OFF |
1. Problem Description
Defect Description | POWDER COATING NOT OK-POWDER COATING PEEL OFF |
Detection Stage | Inprocess |
Problem Severity | Aesthetic |
NG Quantity | 1168 |
Is Defect Repeatative? | No |
Defect Sketch / Photo |
Supplier Communication Details
Quality Head Email ID | quality.premier@sanghavigroup.co.in |
Plant Head/CEO Email ID | prabhune.girish@sanghavigroup.co.in |
MD Email ID | sanghavi.rajesh@sanghavigroup.co.in |
2. Stock Details & action taken for NG parts
Location | ETL End | Warehouse | Transit | Supplier FG | Supplier WIP | Total |
---|---|---|---|---|---|---|
Total Qty |
1200
|
0
|
0
|
0
|
0
|
1200
|
Check Qty |
1200
|
0
|
0
|
0
|
0
|
1200
|
NG Qty |
1166
|
0
|
0
|
0
|
0
|
1166
|
Scrap | 1166 |
Rework | 0 |
Under Deviation | 0 |
Containment Action |
---|
All the material available at Endurance End Segregated by hitting method |
3. Process Flow
Process Flow Description |
---|
RM+Cutting+Forming+Piercing+Vibro+Powder Coating+Final Inspection |
4. Process Details
Process / Operation | Powder Coating at Krishna Coating |
Outsource | Yes |
Machine / Cell | Red wine locator Line |
Machine / Cell No. | Red wine locator |
5. Problem Analysis
Type | Possible Cause | Fact Verification | Jud |
---|---|---|---|
Method | No proper bonding of paint to Locator | At phosphating stage bath concentration not maaintained | X |
Method | Oil traces on parts | -tank heater not working | X |
6. Inspection Method Analysis (Current)
Inspection Method | Other |
Other Inspection Method | Inspection by nail |
Check Point at Final Inspection | Yes |
Checking Freq. | Sampling |
Sampling | No |
Sample Size | 5/100 |
7. Root Cause Analysis (Occurance)
Why 1 | Coating Peel Off |
Why 2 | Phosphating observed week |
Why 3 | Bath concentration observed less |
Why 4 | regular bath analysis not done |
Why 5 | Lab chemist not done analysis |
Root Cause (Occurance) | Phosphating bath concentration not maintained. |
Root Cause Analysis (Outflow)
Why 1 | Coating Peel Off |
Why 2 | Part missed from inspector |
Why 3 | Part peel off not observed during Inspection |
Why 4 | Sampling basis adhesion verification |
Why 5 | sampling frequency not increased |
Root Cause (Outflow) | Due to sampling basis adhesion inspection part could not be cached at final inspection |
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type | Countermeasure Details | Responsibility | Target Date | Actual Date | Status |
---|---|---|---|---|---|
Occurance | Phosphating bath concentration maintained, Degreasing heater Started | Mr.Lokahnde | 01/10/2024 | 15/10/2024 | Completed |
Outflow | Sampling frequency for Adhesion increased, Double sampling started | Mr.Lokhande | 01/10/2024 | 15/10/2024 | Completed |
9. Inspection Method After Customer Complaint
Change In Inspection System | Yes |
Change Details | Double sampling inspection for adhesion started |
Inspection Method | Other |
Other Inspection Method | Cross Adhesion |
Check Point at Final Inspection | Yes |
Checking Freq. | Sampling |
Sampling | No |
Sample Size | 5/100 |
10. Evidance of Countermeasure
Occurance (Before) |
Phosphating Stage Bath Concentration not maintained and Degreasing Heater not working which is started. 1116_Occurance_Before.pdf |
Occurance (After) |
Bath Concentration maintained and Heater Started 1116_Occurance_After.pdf |
Outflow (Before) |
Operator Skill matrix Not Updated 1116_Outflow_Before.pdf |
Outflow (After) |
Training Provided to Final Inspector 1116_Outflow_After.pdf |
11. Horizontal Deployment
Horizontal Deployment Required | Yes |
Applicable Machine / Model / Plant | Brass Gold Locator, Silver Locator |
12. Document Review
Documents | WISOP |
Specify Other Document | OPL Implemented |
13. Effectiveness Of Action
Reviewed Quantity | 500 |
Reason for submission | AFTER TAKING ACTION POWDER COATING FOUND OK- NO POWDER COATING PEEL OFF OBSERVED. |