Request No. - CAR00245
Contractor Assessment Request Details
Assessment Type New
Vendor
Contractor PURSHOTAM CO. PVT. LTD.
Contractor Location PUNE
Contractor Email ID PURSHOTAM CO. PVT. LTD.
Plant Code 1108
 
Preliminary Details For Evaluation
Contractor Type Product Supplier
Name of Company / Contractor Purshotam Company Private Limited
Contact Person Name MURLIDHAR MALI
Contact Number 09168134905
Work Description Laser marking Machine installation and commissioning
Previous ETL Contracts Mr. Shyam Jagdhane
Existing Clientele SHYAM JAGDHANE
Organizational Chart 245_OrganizationalChart_.docx
Employees Head Count 51
Employees Deployed Count at ETL 2
Supervisors Count 1
Is Sub Contractor Nominated ? No
Sub Contractor
Contractors Financial Health & Capability (Turnover in INR) 20CR
C A Certificate 245_CACertificate_.pdf
Does your last two years balance sheet shows profit? Yes
Balance Sheet 245_BalanceSheet_.pdf
Do you have at least 3 years of experience for carrying out similar activity? No
Experience Certificate
 
Section 1 - Mandatory Requirement
Sr.No Requirement Text Options License / Registration No. / Policy No. Attachment Valid Till Score
1License under the Factory Act.1948 / Contract Labor Act / Shop ActComplied1631000310200253245_11__section1_.pdf31.12.20235
2Number of employees authorized to deploy as per licenseComplied6245_12__section1_.pdf31.12.20235
3Is the organization registered for EPF?Complied48876/cc-ii/2334245_13__section1_.pdf31.12.20235
4Is the organization registered for ESIC?Compliedn/4100044766000/002/ins-vi245_14__section1_.pdf31.12.20235
5Is the organization registered for GSTN?Complied27AABCPS994Q1ZG245_15__section1_.pdf31.12.20235
6Workmen compensation Policy / Group InsuranceComplied0239282524245_16__section1_.pdf31.12.20235
7Are workers working hours complied with the current applicable law in the country?Complied2245_17__section1_.pdf31.12.20235
8Are wages paid on the basis of Minimum Wages Act?Complied2245_18__section1_.pdf31.12.20235
9Licensed Electrical Supervisor / Electrician If Applicable (For Electrical Work)Not Complied0
10Any complaint registered against the contractor in past under Labour lawsNot Complied0
 
Total - 40
 
Section 2 - Safety Performance
Sr.No Requirement Text Answer Details Attachment Score
1No. of Accidents (Medical Treatment) in last 2 years0NO5
2No. of Fatalities (Verify from Govt. data / reference check)0NO5
3No. of Lost time injuries as per Factories Act 1948 (Injured person not able to work more than 48 hours from time of accident)0NO5
4No. of Fire Incident in last 2 years0NO5
5Has the organisation been prosecuted for an HSE breach or injury to an employee? Specify nos.0NO5
 
Total - 25
 
Section 3 - General EHS Systems
Sr.No Requirement Text Answer Details Attachment Score
1HSE Policy (Provide evidence by supplying copies of relevant documents)Not Applicable5
2Induction and Training (provide relevant documents)No0
3PPE’s maintained in Good ConditionNo0
4Does the organization regularly inspect and maintain hand tools, machinery (cranes, vehicles, hoists/lifting tools, etc.)Yes5
5Health monitoring of Employees - Medical Check Up Done for employee’s as per Form 7 (date / Fitness Certificate from AFIH doctor)No0
 
Total - 10
 
Section 4 - EHS Practices
Sr.No Requirement Text Answer Details Attachment Score
1Is the contract employee aware of Work Permit System / Work Permit Adherence?Yes5
2Is the organization aware of Method Statement/ Method Statement Adherence?Yes5
3Are the contract employees aware of Emergency Response Procedure?Yes5
4Has the organization conducted a HIRA study in past / or as a part of current practice?Yes5
5Does the organization have and follow safe work procedures, documents which define how risks relevant to the contracted activities are managed?Yes5
 
Total - 25
 
Section 5 - Plant and Equipment
Sr.No Requirement Text Answer Details Attachment Score
1Are the tools and equipment used in good working condition?Yeswe have standared tool e.g. Allenky set , spanner set, screwdriver set only5
2Do the tools and equipment comply with standards such as ISI Mark / Energy Efficient 5 star rating guidelines?YesTaparia make only5
3Is the holding handle of equipment in good condition?Yes5
4Are all plants and equipment compliant with the safety requirements? (including not damaged cables, no loose connections, equipped with 3 pin top)Yes5
5Do contract employees have correct licenses / certificates to operate the plants and equipment?Yes5
 
Total - 25
 
Total Score
Section Score
Section 1
Mandetory Requirement
40
Section 2
Safety Performance & System Awareness
25
Section 3
General EHS Systems
10
Section 4
EHS Practices
25
Section 5
Plant and Equipment
25
Total Score
125
 
The overall ranking of pre-qualification is 83 % (Semi Professional)
 
 
Approval Process History
Role Employee Request Status Comments Updated On