QFR No - 7000923677
Defect Details
NC No. 7000923677
NC Date 21/06/2023
NC Submission Date
Part No. S2DP02902B
Part Name EXTENSION K55G
Supplier Name & Code 100106-SHARP ENGINEERS.
ETL Plant 1136-ETL Suspension Sanand
Defect Details RUSTY-Rusty
 
1. Problem Description
Defect Description Material rusty
Detection Stage Receipt
Problem Severity Aesthetic
NG Quantity 1090
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID quality@apw3.co.in
Plant Head/CEO Email ID kurund.ma@sharp-engineers.com
MD Email ID urkhandelwal@sharp-engineers.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
5000
5000
0
1000
0
11000
Check Qty
5000
5000
0
1000
0
11000
NG Qty
1090
0
0
0
0
1090
 
Scrap 0
Rework 1060
Under Deviation 0
Containment Action
Segregation done at WIP and FG and defective part removed from ok part.
 
3. Process Flow
Process Flow Description
10) RM Inward 20) Storage 30) Material Issue 40) Parting & Drilling 50) ID Chamfer 60) Tapping 70) OD grinding 80) Final Inspection 90) Pre-dispatch inspection100) Packing & dispatch
 
4. Process Details
Process / Operation Storage (Warehouse)
Outsource Yes
Machine / Cell NA
Machine / Cell No. NA
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MachineImproper preventive maintenancePreventive maintenance plan evident as per P/MNT/01 and being followed as per F/MNT/07O
MethodMaterial Handling( Material should be store on the pallet at warehouse)Material kept on ground floor instead of pallet.X
ToolInsert/Tool/Drill worn outTool life monitoring as per defined tool life monitoring.O
MaterialIncorrect Raw MaterialMaterial observed as per customer requirement Ø16.10 EN1A , MTC verified as per drawing specificatioO
ManUn-skilled OperatorStage wise skill matrix and operator license are evident as per F/HR/06O
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Warehouse storage
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size Bag to Bag
7. Root Cause Analysis (Occurance)
Why 1 Extension K55 Rusty
Why 2 Material storage on the ground floor
Why 3 Pallet not available.
Why 4 Improper material storage by old transporter (Mumbai-Gujrat transport)
Why 5
Root Cause (Occurance) Material storage on the ground floor, Pallet not available. (Mumbai-Gujrat transport)
 
Root Cause Analysis (Outflow)
Why 1 Extension K55 Rusty part reached to ETL
Why 2 RP oil dried after 20 days of oil application
Why 3 Rust preventive oil PANOL RP DW 68 being used
Why 4 Defined by system.
Why 5
Root Cause (Outflow) Rust preventive oil PANOL RP DW 68 being used, less life of rust preventive oil(Only 15 days after oil application)
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowRust preventive oil VORSTAB is being used, excess life of rust preventive oil. (@1 month)Mr. Shaikh L.N.04/07/202304/07/2023Completed
OccuranceProper storage identified at warehouse material and provided pallet for storageMr. Shaikh L.N.04/07/202304/07/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details RP oil has been changed
Inspection Method Other
Other Inspection Method Visually
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 1:1
10. Evidance of Countermeasure
Occurance (Before) Material storage on the ground floor, Pallet not available. (Mumbai-Gujrat transport)
490_Occurance_Before.pptx
Occurance (After) Pallet made available. (Anjali logistic )
490_Occurance_After.pptx
Outflow (Before) Rust preventive oil PANOL RP DW 68 being used, less life of rust preventive oil(Only 15 days after oil application)
490_Outflow_Before.pptx
Outflow (After) Rust preventive oil VORSTAB is being used, excess life of rust preventive oil. (@1 month)
490_Outflow_After.pptx
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant NA
 
12. Document Review
Documents ControlPlan, PFMEA, WISOP, InspCheckSheet
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 1
Reason for submission No rust observed in fresh lots.