QFR No - 8000833174
Defect Details
NC No. 8000833174
NC Date 17/06/2023
NC Submission Date
Part No. B2SG00426O
Part Name CBS ACTUATING LINK
Supplier Name & Code 100144-AURANGABAD PRESSINGS
ETL Plant 1156-ETL Disc Brake P'Nagar
Defect Details PATCH MARK ON SPOT FACE.-PLATING MISS
 
1. Problem Description
Defect Description Plating miss
Detection Stage Inprocess
Problem Severity Aesthetic
NG Quantity 50
Is Defect Repeatative? Yes
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID quality@apw3.co.in
Plant Head/CEO Email ID aurangabadpressings@apw3.co.in
MD Email ID shashikant@apw3.co.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
4500
0
0
0
0
4500
Check Qty
4500
0
0
0
0
4500
NG Qty
647
0
0
0
0
647
 
Scrap 50
Rework 0
Under Deviation 597
Containment Action
Sagration
 
3. Process Flow
Process Flow Description
Blanking /piercing/1st forming/forming/drilling/plating
 
4. Process Details
Process / Operation Plating
Outsource Yes
Machine / Cell Plating Shop
Machine / Cell No. 01
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodPassivation timeTime increasedO
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual inspection
Check Point at Final Inspection No
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 Passivation time less
Why 2 operator awarness
Why 3 need Training
Why 4
Why 5
Root Cause (Occurance) 1
 
Root Cause Analysis (Outflow)
Why 1 Need Training to operator
Why 2 awarness about component
Why 3
Why 4
Why 5
Root Cause (Outflow) Less passivation time
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OutflowPassivation time lessOperator27/06/2023Pending
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 100% visual inspection
Inspection Method Other
Other Inspection Method Visual inspection
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) one
483_Occurance_Before.pdf
Occurance (After) no
483_Occurance_After.pdf
Outflow (Before) one
483_Outflow_Before.pdf
Outflow (After) one
483_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant All Plating component
 
12. Document Review
Documents WISOP, InspCheckSheet
Specify Other Document PDI Report
 
13. Effectiveness Of Action
Reviewed Quantity
Reason for submission