QFR No - 8000842148
Defect Details
NC No. 8000842148
NC Date 26/08/2023
NC Submission Date
Part No. F2GN25602B
Part Name MAIN SPRING Ø33 SPD
Supplier Name & Code 101225-HELICAL SPRINGS
ETL Plant 1118-ETL E-92,93 Suspension
Defect Details LENGTH OVERSIZE-FREE LENGTH OVERSIZE OBS.375MM
 
1. Problem Description
Defect Description Free length over size by 3 mm.
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 229
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID quality.waluj@helicalsprings.in
Plant Head/CEO Email ID shaikhmoin@helicalsprings.in
MD Email ID ataneja@helicalsprings.in
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1500
0
0
800
1000
3300
Check Qty
1500
0
0
800
1000
3300
NG Qty
229
0
0
0
0
229
 
Scrap 229
Rework 0
Under Deviation 0
Containment Action
Problem Verified And Checked All Material in Stock.
 
3. Process Flow
Process Flow Description
Raw Material Receipt & Inspection, Coiling, Stress Relieving, End Grinding, Shot Peening, Scragging, Length & Wavyness checking, Strain-aging, Surface Finish- Oiling, Final Inspection/ PDI, Packing, Dispatch.
 
4. Process Details
Process / Operation Satge Of Packing.
Outsource No
Machine / Cell NA
Machine / Cell No. NA
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ManWrong Material MixSkill Matrix Found OkO
ToolNACheck Sheet Found OkO
MaterialRMTC Found OkTC VerificationO
MethodArea Not Identified For New Developments Parts.Stock sheet VerificationX
MachineHerdonVerified OkO
 
6. Inspection Method Analysis (Current)
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
7. Root Cause Analysis (Occurance)
Why 1 Length Oversize
Why 2 Other Material Mixed With Ok Parts
Why 3 Both Are The Similar Looking Items
Why 4 Storing In Same Place
Why 5 Due To No Route cards Available For NPD Parts.
Root Cause (Occurance) No Identification (Route Card) Placed in NPD Parts.
 
Root Cause Analysis (Outflow)
Why 1 Length Oversize
Why 2 Not Detected During PDIR Due To Less Qty.
Why 3 PDIR Done On Sampling Basis.
Why 4
Why 5
Root Cause (Outflow) Sample Size Not Sufficient To Detect The Issue (Only 5 Nos for 1000)
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceRoute Cards Started For Development Parts.Production30/08/2023Completed
OutflowSampling Plan Increased For Next 3 Lots ( 20 Nos Per 1000Nos)QA30/08/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Sampling Plan Increased.
Inspection Method Gauge
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 100%
10. Evidance of Countermeasure
Occurance (Before) Route Cards Not Available For NPD Parts
535_Occurance_Before.pdf
Occurance (After) Route Card Available For NPD Parts
535_Occurance_After.pdf
Outflow (Before) Area Not Defined For NPD Parts.
535_Outflow_Before.pdf
Outflow (After) Area Defined and Training Given to Packing and Dispatch Station Employee.
535_Outflow_After.pdf
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant All Similar Parts
 
12. Document Review
Documents ProcessFlowChart, InspCheckSheet
Specify Other Document Route Cards
 
13. Effectiveness Of Action
Reviewed Quantity 10000
Reason for submission No any concern observed after action plan submitted.