QFR No - 7000951326
Defect Details
NC No. 7000951326
NC Date 09/10/2023
NC Submission Date
Part No. F2HL00402B
Part Name OIL LOCK COLLAR (HMC-31/K38G)
Supplier Name & Code 100106-SHARP ENGINEERS.
ETL Plant 1136-ETL Suspension Sanand
Defect Details MIX UP OTHER MODEL-Wrong part
 
1. Problem Description
Defect Description Other model mixing parts found in oil lock collar
Detection Stage Receipt
Problem Severity Fitment
NG Quantity 123
Is Defect Repeatative? Yes
Defect Sketch / Photo ekltmoemj1irgygxc21udo1u.jpg
Supplier Communication Details
Quality Head Email ID quality@apw3.co.in
Plant Head/CEO Email ID kurund.ma@sharp-engineers.com
MD Email ID urkhandelwal@sharp-engineers.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
6000
5000
5000
10000
5000
31000
Check Qty
6000
5000
5000
10000
5000
31000
NG Qty
123
0
0
0
0
123
 
Scrap 0
Rework 123
Under Deviation 0
Containment Action
All the suspected material has been cross checked and dispatched.
 
3. Process Flow
Process Flow Description
10) RM Inward 20) RM Storage 30) Parting & Chamfering 40) ID Chamfering 50) OD grinding 60) Plating (Outsource) 70) 80) Inward Inspection 90) Final Inspection 100) Packing & Dispatch
 
4. Process Details
Process / Operation Packing
Outsource No
Machine / Cell Final Inspection
Machine / Cell No. Q Gate
5. Problem Analysis
Type Possible Cause Fact Verification Jud
MethodOperator Working Method WrongSOP/WI available on machine and operator aware about it and being followed.O
ManUn-skilled OperatorStage wise skill matrix and operator license are not evident as per F/HR/06X
MaterialIncorrect RM gradeThird part inspection verified for chemical composition and hardness testing as per requirement.O
ToolTool life monitoring inadequateTool life for all the tool i.e. forming tool, drill, and insert are defined and recorded as per freqO
MachineImproper preventive maintenancePreventive maintenance plan evident as per P/MNT/01 and being followed as per F/MNT/07O
 
6. Inspection Method Analysis (Current)
Inspection Method Other
Other Inspection Method Visual
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size Bag To Bag
7. Root Cause Analysis (Occurance)
Why 1 Wrong Part reached at ETL
Why 2 Two different part kept at same location.
Why 3 Packing was same.
Why 4 Not detected from outside.
Why 5 Transparent poly bag not in used.
Root Cause (Occurance) Transparent poly bag not in used at BSR stage.
 
Root Cause Analysis (Outflow)
Why 1 Wrong Part reached at ETL
Why 2 Incorrect material selection form BSR while dispatching.
Why 3 Person not aware about the part
Why 4 SOP & Analysis: Material handling of Finish Product being supplied to Endurance not displayed at BSR.
Why 5
Root Cause (Outflow) SOP & Analysis: Material handling of Finish Product being supplied to Endurance not displayed at BSR.
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
OccuranceTransparent poly bag are being used at BSR stage.Mr. Ganesh Mande17/10/202317/10/2023Completed
OutflowSOP & Analysis: Material handling of Finish Product being supplied to Endurance displayed at BSR.Mr. Ganesh Mande17/10/202317/10/2023Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details 100%inspection
Inspection Method Other
Other Inspection Method Visual Inspection
Check Point at Final Inspection Yes
Checking Freq. 100%
Sampling No
Sample Size 1:1
10. Evidance of Countermeasure
Occurance (Before) Transparent poly bag not in used at BSR stage.
573_Occurance_Before.pptx
Occurance (After) Transparent poly bag are being used at BSR stage.
573_Occurance_After.pptx
Outflow (Before) SOP & Analysis: Material handling of Finish Product being supplied to Endurance not displayed at BSR.
573_Outflow_Before.pptx
Outflow (After) SOP & Analysis: Material handling of Finish Product being supplied to Endurance displayed at BSR.
573_Outflow_After.pptx
 
11. Horizontal Deployment
Horizontal Deployment Required No
Applicable Machine / Model / Plant NA
 
12. Document Review
Documents PFMEA, WISOP, PackingStd
Specify Other Document NA
 
13. Effectiveness Of Action
Reviewed Quantity 5
Reason for submission Wrong model (Mix up other model)