QFR No - 8000874506
Defect Details
NC No. 8000874506
NC Date 16/05/2024
NC Submission Date
Part No. 520DZ00212
Part Name FORK BOLT K60-(DS181012)
Supplier Name & Code 100189-SANGKAJ STEEL PVT LTD.
ETL Plant 1117-ETL K-228/9 Suspension
Defect Details NOT AS PER SPECIFICATION-DIMN. 7.5 UNDERSIZE - (4.0+0.1) + (3.5 )
 
1. Problem Description
Defect Description DIMN. 7.5 UNDERSIZE - (4.0+0.1) + (3.5 )
Detection Stage Inprocess
Problem Severity Fitment
NG Quantity 402
Is Defect Repeatative? No
Defect Sketch / Photo
Supplier Communication Details
Quality Head Email ID qualityassurance@sangkaj.com
Plant Head/CEO Email ID steel@sangkaj.com
MD Email ID anirudh.2007@hotmail.com
2. Stock Details & action taken for NG parts
Location ETL End Warehouse Transit Supplier FG Supplier WIP Total
Total Qty
1600
0
0
800
1000
3400
Check Qty
1600
0
0
800
1000
3400
NG Qty
402
0
0
36
0
438
 
Scrap 436
Rework 0
Under Deviation 0
Containment Action
All material at ETL End & at Sangkaj Steel is segregated, Defective Qty is scrapped.
 
3. Process Flow
Process Flow Description
RM Inward-RM Inward inspection-Traub Machining(Semi-finish Blank)-Grinding-Tapping-Thread Rolling-Plating-Final Inspection-Packing & dispatch
 
4. Process Details
Process / Operation Traub Machining
Outsource Yes
Machine / Cell Traub machine
Machine / Cell No. 04
5. Problem Analysis
Type Possible Cause Fact Verification Jud
ToolTool Worn OutWorn Out Tool Doesn`t Cause huge VariationX
ManNew or Unskilled operatorExperienced & Skilled Operator is deputed for productionX
MaterialInput Material not okPart manufactured through Continuous bar Feeding & RM Bar Found OKX
MethodInadequate Inspection MethodNo Checkpoint for the Parameter in the Inprocess & in Final Inspection.O
MachineVariation due to MachineMachine Condition found okX
ToolWrong Tool Usedpart produced by using another tool used for similar category PartsO
 
6. Inspection Method Analysis (Current)
Inspection Method Instrument
Other Inspection Method
Check Point at Final Inspection No
Checking Freq. Sampling
Sampling No
Sample Size 50:500
7. Root Cause Analysis (Occurance)
Why 1 7.50 mm Dimension found undersize
Why 2 Wrong forming Tool used for machining
Why 3 Forming Tools not identified with Part Names.
Why 4 Tool Identification not mentioned in the WI
Why 5
Root Cause (Occurance) Tool Identification not mentioned in the WI
 
Root Cause Analysis (Outflow)
Why 1 7.50 mm Dimension found undersize
Why 2 Defective Parts Skipped from Inspection.
Why 3 During Inspection this parameter is not checked
Why 4 Verification of this parameter not Included in Inspection Checklists.
Why 5 Inspection Checklists are inadequate.
Root Cause (Outflow) Inspection Checklists are Inadequate
 
8. Countermeasure ( Occurrence , Outflow & System side Actions )
Type Countermeasure Details Responsibility Target Date Actual Date Status
Outflow7.50mm Dimension Verification added in Following Checklists- 1. Supplier In-process Inspection Report, 2.Supplier PDIR Report, 3.Sangkaj Steel`s Inward Inspection Report 4.PDIRMr. Anil Chaudhari03/06/202403/06/2024Completed
Occurance1.Forming Tools are identified with Part names. 2.Setting WI Updated, it is mentioned in the WI that Every Tool should have Part Names on them.Mr. Anil Chaudhari03/06/202403/06/2024Completed
 
9. Inspection Method After Customer Complaint
Change In Inspection System Yes
Change Details Dimension 3.50mm Added In Supplier PDIR, Supplier In-process Inspection Report, Inward Inspection & PDI Report of Sangkaj Steel. Inspection will be Followed on Sampling Basis.
Inspection Method Instrument
Other Inspection Method
Check Point at Final Inspection Yes
Checking Freq. Sampling
Sampling No
Sample Size 50:500
10. Evidance of Countermeasure
Occurance (Before) No Identification of Forming Tool with part Names
809_Occurance_Before.pptx
Occurance (After) Part Names Engraved on the Tool with manual Engraving Machine
809_Occurance_After.pptx
Outflow (Before) No Checkpoint Available for this Dimension
809_Outflow_Before.pptx
Outflow (After) Checkpoint added in the PDIR, Hourly inspection and Inward Inspection Report
809_Outflow_After.pptx
 
11. Horizontal Deployment
Horizontal Deployment Required Yes
Applicable Machine / Model / Plant Fork Bolt JD, 5TSF
 
12. Document Review
Documents ControlPlan, InspCheckSheet
Specify Other Document PDIR
 
13. Effectiveness Of Action
Reviewed Quantity 50
Reason for submission Judgment wrong Occurrence side root cause can do better